{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4FJ200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4FJ200","canonicalUrl":"https://aoctrl.com/schneider/LX4FJ200","factsUrl":"https://aoctrl.com/api/mcp/products/LX4FJ200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys FJ series contactor coil, LX4FJ200, 200 V DC control voltage, DC low-consumption type, active production.","salesMarkdown":"The LX4FJ200 is a 200 V DC contactor coil from the TeSys FJ series, designed as a replacement or build-up coil for TeSys FJ contactors. It's a DC low-consumption type, meaning the hold-in power draw is significantly lower than the inrush — the holding resistance at 20 °C is 9334 Ω versus 37.1 Ω for the inrush coil, so once the contactor seals, the coil driver sees a fraction of the initial current. The operating time is 45...60 ms opening and 50...60 ms closing, which is typical for a contactor of this frame size and keeps the switching sequence predictable for interlocking logic. The coil ships without a built-in suppressor module, so you'll need to add a flyback diode or RC snubber across the coil terminals if the DC control circuit drives it from a PLC output or relay — the inductive kick from a 200 V DC coil can damage solid-state outputs or cause noise issues on a shared 24 V DC backplane if left unsuppressed. ## Control voltage and operating limits Rated control circuit voltage is 200 V DC. The operational voltage limits are 0.85...1.1 Uc at 131 °F (55 °C), so the coil reliably picks up between 170 V DC and 220 V DC. Drop-out occurs at 0.2...0.35 Uc at 131 °F (55 °C), meaning the contactor drops out between 40 V DC and 70 V DC — wide enough to ride through minor sags but drops cleanly on a controlled shutdown. Ambient temperature range for operation is 23...131 °F (-5...55 °C), which covers most indoor control panel environments.","metaTitle":"TeSys LX4FJ200 Contactor Coil, 200 V DC, Active","metaDescription":"TeSys LX4FJ200 contactor coil, 200 V DC control voltage, DC low-consumption design. Active lifecycle. Operating time 45-60 ms open, 50-60 ms close. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX4FJ200","Category":"18401-WORLD SERVICE PARTS(CTR ACCESS)","description":"contactor coil - FJ - 200 V DC","Operating time":"45...60 ms opening 50...60 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX4FJ","Average resistance":"37.1 Ohm inrush 68 °F (20 °C) 9334 Ohm holding 68 °F (20 °C)","Control circuit type":"DC low consumption","Nbr. of units in pkg.":"1","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200 V DC","Control circuit voltage limits":"Drop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/93c5d66f2ef6eea68c3cb8dc9b24d05d.pdf","sourceUrl":"https://www.se.com/us/en/product/LX4FJ200/contactor-coil-fj-200-v-dc/"},"ai":{"faq":[{"question":"What is LX4FJ200's listed range (TeSys) on this component line?","answer":"The LX4FJ200 belongs to the TeSys range, which is Schneider Electric's global line of contactors, motor starters, and control relays."},{"question":"What is LX4FJ200's listed category (18401-WORLD SERVICE PARTS(CTR ACCESS)) on this component line?","answer":"The category is 18401-WORLD SERVICE PARTS(CTR ACCESS), indicating this is a service-part coil for contactors, not a main catalog product. It's stocked as a replacement component."},{"question":"Does the LX4FJ200 include a built-in surge suppressor?","answer":"No, this coil is listed as 'Without built-in suppressor module'. You must add an external flyback diode or RC snubber when driving it from a DC control circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4FJ200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4FJ200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}