{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4FL090","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4FL090","canonicalUrl":"https://aoctrl.com/schneider/LX4FL090","factsUrl":"https://aoctrl.com/api/mcp/products/LX4FL090","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX4FL090, contactor coil, 90 V DC control voltage, 40...50 ms opening, 60...70 ms closing, without built-in suppressor module.","salesMarkdown":"The Schneider Electric LX4FL090 is a replacement contactor coil from the TeSys range, designed to drive the FK-series contactor armature. It operates on a 90 V DC control circuit with low-consumption DC coil technology and no built-in suppressor module — so if your existing circuit relied on a free-wheel diode or RC snubber at the coil terminals, that external suppression must be retained or added per the panel schematic. Opening time is 40 to 50 ms; closing time is 60 to 70 ms. Those figures matter when you're coordinating contactor timing in a motor starter or reversing circuit — the coil's mechanical travel sets the minimum interval before the auxiliary contacts change state. ## Control voltage limits and dropout behaviour The coil is rated for a control circuit voltage of 90 V DC, with an operational range of 0.85 to 1.1 Uc at 131 °F (55 °C). Dropout occurs between 0.2 and 0.35 Uc at the same temperature. That means the contactor will hold in down to about 76.5 V DC and will reliably drop out below about 31.5 V DC — important for brownout ride-through or for verifying that a low-voltage condition actually opens the power contacts. Ambient operating temperature is -5 to 55 °C (23 to 131 °F). If the panel ambient runs higher, the coil's thermal rise plus ambient may shift the dropout point; per the datasheet, the limits are stated at 55 °C, so derating above that is not covered by these figures.","metaTitle":"Schneider TeSys LX4FL090 Contactor Coil, 90 V DC","metaDescription":"TeSys LX4FL090 contactor coil, 90 V DC control voltage, 40-50 ms opening / 60-70 ms closing. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"90 V DC","Operating Time":"40...50 ms opening 60...70 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"DC low consumption","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/49c380f5c29e41748673990e6462d286.pdf","sourceUrl":"https://www.se.com/th/en/product/LX4FL090/contactor-coil-fk-90-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4FL090/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4FL090","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4FL090 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}