{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FF070","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FF070","canonicalUrl":"https://aoctrl.com/schneider/LX9FF070","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FF070","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LX9FF070 specific contactor coil, 70 V AC 40-400 Hz low consumption, without built-in suppressor module.","salesMarkdown":"The LX9FF070 is a specific replacement coil for Schneider Electric TeSys F contactors, wound for 70 V AC control at 40 to 400 Hz. It is a low-consumption design — meaning the inrush and hold-in power are deliberately kept down to reduce thermal stress on the panel wiring and the contactor itself. The coil draws 690 to 855 VA inrush at 68 °F (20 °C), then settles to 6.6 to 8.1 VA holding. That inrush-to-hold ratio is typical of AC-operated contactor coils; the holding VA is low enough that a standard 70 V control transformer can supply multiple coils without excessive sag. Coil resistance measures 6.18 Ω inrush and 190.8 Ω holding at 68 °F (20 °C). The opening time is 130 ms, closing 35 ms — the asymmetry is normal for AC coils; the slower opening is inherent to the magnetic circuit decay. ## Control voltage limits and operating window The coil holds its armature across 0.85 to 1.1 Uc at 131 °F (55 °C), so it stays pulled in from about 59.5 V to 77 V AC. Drop-out occurs between 0.35 and 0.55 Uc — roughly 24.5 to 38.5 V AC — which is a standard margin for AC contactor coils and ensures positive release when the control signal is removed. Rated operating temperature is -5 to 55 °C (23 to 131 °F). The maximum operating rate at 55 °C is 2400 cycles per hour — enough for most motor starting and resistive load switching cycles, but not for high-speed jogging or repetitive inrush applications. Schneider Electric lists the LX9FF070 as obsolete. Because this is a specific contactor coil — not a universal replacement — verify that the contactor frame and armature match the TeSys F series before committing the order. The coil has no built-in suppressor module, so an external RC snubber or varistor must be added across the coil if the control circuit requires one for EMI compliance or contact protection. The 70 V AC control voltage is uncommon in North American panels (typically 120 V or 24 V) but standard in many European and Asian installations where 70 V control transformers are used. Heat dissipation of 5.9 to 7.2 W means the coil contributes measurable heat inside the enclosure. In a densely packed panel with multiple TeSys F contactors, the cumulative coil dissipation must be factored into the thermal budget — especially if the enclosure is sealed or has limited ventilation. The coil itself is rarely the life-limiting component in the contactor assembly; the main contacts wear out first under load switching.","metaTitle":"Schneider Electric LX9FF070 TeSys F Contactor Coil, 70 V AC","metaDescription":"Obsolete TeSys F specific contactor coil, 70 V AC 40-400 Hz low consumption. Sourced to order against RFQ. 130 ms opening, 35 ms closing. No built-in suppressor.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"70 V AC 40...400 Hz","Operating Time":"130 ms opening 35 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cf2f3611e2bfa7861d457c88a60c94d1.pdf","sourceUrl":"https://www.se.com/us/en/product/LX9FF070/tesys-f-specific-contactor-coil-70-v-ac-40-400-hz-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FF070/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FF070","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FF070 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}