{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FF080","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FF080","canonicalUrl":"https://aoctrl.com/schneider/LX9FF080","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FF080","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F specific contactor coil, 80 V AC 40..400 Hz low consumption, LX9FF080.","salesMarkdown":"The LX9FF080 is a specific contactor coil from the TeSys F range, designed to operate at 80 V AC (40–400 Hz) with low-consumption control circuit technology. It is the replacement coil for TeSys F contactors that require a separate, field-replaceable coil — not a built-in or integrated coil assembly. The coil draws 690–855 VA inrush at 20 °C and settles to 6.6–8.1 VA holding power, with an average resistance of 7.54 Ω inrush and 230.8 Ω holding at 20 °C. Heat dissipation runs 5.9–7.2 W under steady-state operation. Opening time is 130 ms, closing time 35 ms. ## Control voltage and operating limits The coil operates across 0.85–1.1 Uc (68–88 V AC) at 55 °C and drops out between 0.35–0.55 Uc (28–44 V AC). This means the coil will hold in down to about 68 V and will reliably drop out below 44 V — important for brownout ride-through or undervoltage release coordination. Ambient temperature range for operation is -5 to 55 °C. The coil has no built-in suppressor module, so an external RC snubber or varistor must be added across the coil terminals if driving from a PLC output or solid-state relay to prevent inductive kickback damage. This coil mounts onto TeSys F contactor bodies (LC1F range) as a field-replaceable component. The contactor itself is typically DIN-rail or panel-mounted in motor control centers, pump panels, and conveyor starters. The coil's AC control voltage means it is suited for installations where 80 V control transformers are already in place — common in older European-spec panels or retrofit scenarios.","metaTitle":"TeSys LX9FF080 Contactor Coil, 80 VAC, Obsolete","metaDescription":"TeSys LX9FF080 specific contactor coil, 80 VAC 40-400 Hz low consumption. Obsolete per manufacturer. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Operating time":"130 ms opening 35 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"5.9...7.2 W","Device short name":"LX9FF","Average resistance":"7.54 Ohm inrush 68 °F (20 °C) 230.8 Ohm holding 68 °F (20 °C)","Inrush power in VA":"690...855 VA 40...400 Hz (at 68 °F (20 °C))","Control circuit type":"AC 40...400 Hz low consumption","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Product or Component Type":"Specific contactor coil","[Uc] control circuit voltage":"80 V AC 40...400 Hz","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))","Hold-in power consumption in VA":"6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/18630c61e4bd01313f492241604a24f8.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FF080/tesys-f-specific-contactor-coil-80-v-ac-40-400-hz-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FF080/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LX9FF080?","answer":"No official successor order code is listed. Any replacement must be verified for pin-compatibility and electrical characteristics against the TeSys F contactor body it mates with. The coil footprint and mounting interface are specific to the LC1F contactor range."},{"question":"What is the control voltage and frequency range?","answer":"The LX9FF080 is rated for 80 V AC control voltage, 40–400 Hz. It operates between 68–88 V AC (0.85–1.1 Uc) and drops out between 28–44 V AC (0.35–0.55 Uc) at 55 °C."},{"question":"Does the coil include a built-in suppressor?","answer":"No, the coil technology is listed as 'without built-in suppressor module'. An external RC snubber or varistor must be added across the coil terminals when driven by a PLC output or solid-state relay."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FF080","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FF080 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}