{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FF170","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FF170","canonicalUrl":"https://aoctrl.com/schneider/LX9FF170","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FF170","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, specific contactor coil, LX9FF170, 170 V AC 40..400 Hz low consumption.","salesMarkdown":"The LX9FF170 is a specific contactor coil from the TeSys F range, designed for 170 V AC control circuits at 40 to 400 Hz with low consumption technology. It is a replacement or spare coil for TeSys F contactors, not a complete contactor — the coil alone, without a built-in suppressor module. Rated for continuous duty in a control panel environment, the LX9FF170 operates within an ambient temperature range of -5 to 55 °C. The coil draws 690 to 855 VA inrush at 20 °C, then settles to 6.6 to 8.1 VA holding — the inrush figure determines the sizing of the control transformer and the contactor's pick-up reliability, while the hold-in VA governs continuous heat load in the panel. Coil resistance measures 37.55 ohms inrush and 1453 ohms holding at 20 °C, which confirms the low-hold-power design and helps with PLC output drive calculations if a relay interface is used. Operational voltage range is 0.85 to 1.1 times Uc at 55 °C; drop-out occurs between 0.35 and 0.55 Uc. Opening time is 130 ms, closing time 35 ms — the asymmetry matters for sequencing: the slower opening gives the arc more time to extinguish on break, while the fast close minimizes pre-strike wear on the main contacts. ## Thermal and mechanical endurance Heat dissipation runs 5.9 to 7.2 W in the holding state — this is the continuous thermal load the coil adds to the enclosure, relevant for panel thermal calculations when multiple coils are energized simultaneously.","metaTitle":"Schneider LX9FF170 TeSys F contactor coil, 170 V AC","metaDescription":"TeSys F specific contactor coil, 170 V AC 40-400 Hz low consumption. Active production, 130 ms opening, 35 ms closing. Order LX9FF170 from authorized channel.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"170 V AC 40...400 Hz","Operating Time":"130 ms opening 35 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05c4704680f87b2a65a05630ab5027b1.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FF170/tesys-f-specific-contactor-coil-170-v-ac-40-400-hz-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FF170/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FF170","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FF170 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}