{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FH0952","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FH0952","canonicalUrl":"https://aoctrl.com/schneider/LX9FH0952","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FH0952","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F specific contactor coil, 95 V AC 40..400 Hz low consumption, LX9FH0952.","salesMarkdown":"The LX9FH0952 is a specific contactor coil from the TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It operates on a 95 V AC control circuit at 40 to 400 Hz, with low-consumption coil technology. This coil does not include a built-in suppressor module, so you will need to add an external RC snubber or varistor across the coil terminals if your application requires suppression of switching transients — common on PLC-driven or electronic control circuits. The coil draws 560 to 660 VA inrush at 68 °F (20 °C) across the 40-400 Hz range, dropping to 8 to 10 VA holding. That inrush figure tells you the momentary load on your control transformer when the contactor pulls in — make sure your 95 V AC supply can deliver that surge without dropping below the 0.85 Uc operational limit (80.75 V AC at 131 °F). Coil resistance measures 12.18 Ω inrush and 305 Ω holding at 68 °F (20 °C). The holding resistance is what determines steady-state current draw — roughly 0.31 A at 95 V AC — useful for sizing control circuit fusing. Heat dissipation runs 8.4 to 10.4 W. In a densely packed panel, that heat adds up; allow natural convection around the contactor or keep spacing per TeSys F guidelines. Opening time is 25 ms, closing time 45 ms. That 45 ms pull-in delay matters for sequencing logic — if you need faster response, this coil is not the pick. ## Mechanical life and operating rate That is one cycle per second — fine for most motor starting and general switching, but not for high-speed applications like rapid reversing or jogging duty.","metaTitle":"TeSys LX9FH0952 contactor coil, 95 V AC 40-400 Hz","metaDescription":"TeSys F specific contactor coil, 95 V AC 40-400 Hz low consumption. Active production. Inrush 560-660 VA, hold 8-10 VA. Order LX9FH0952.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX9FH0952","Category":"22341-CONTACTOR,D,K,&F ACCESS","description":"TeSys F - specific contactor coil - 95 V AC 40..400 Hz low consumption","Operating time":"25 ms opening 45 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"8.4...10.4 W","Device short name":"LX9FH","Average resistance":"12.18 Ohm inrush 68 °F (20 °C) 305 Ohm holding 68 °F (20 °C)","Inrush power in VA":"560...660 VA 40...400 Hz (at 68 °F (20 °C))","Control circuit type":"AC 40...400 Hz low consumption","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"3600 cyc/h 131 °F (55 °C)","Product or Component Type":"Specific contactor coil","[Uc] control circuit voltage":"95 V AC 40...400 Hz","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))","Hold-in power consumption in VA":"8...10 VA 40...400 Hz (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/498b70ad7283c8353d7243844d2294d8.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FH0952/tesys-f-specific-contactor-coil-95-v-ac-40-400-hz-low-consumption/"},"ai":{"faq":[{"question":"What is the control voltage for LX9FH0952?","answer":"95 V AC at 40 to 400 Hz, low-consumption type. Operational limits are 0.85 to 1.1 Uc (80.75 to 104.5 V AC at 131 °F); dropout occurs between 0.35 and 0.55 Uc (33.25 to 52.25 V AC)."},{"question":"Does this coil include a built-in suppressor?","answer":"No, the coil technology is listed as 'without built-in suppressor module'. You will need to add an external RC snubber or varistor if your control circuit requires transient suppression."},{"question":"What is the inrush and holding VA for this coil?","answer":"Inrush is 560 to 660 VA at 68 °F (20 °C) across the 40-400 Hz range. Holding power consumption is 8 to 10 VA at the same conditions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FH0952","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FH0952 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}