{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FH1902","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FH1902","canonicalUrl":"https://aoctrl.com/schneider/LX9FH1902","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FH1902","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F specific contactor coil, LX9FH1902, 190 V AC 40-400 Hz low consumption, inrush 560-660 VA, hold-in 8-10 VA.","salesMarkdown":"The LX9FH1902 is a specific contactor coil from the Schneider Electric TeSys F range, designed as the replaceable coil assembly for TeSys F contactors. It operates on a 190 V AC control circuit at 40-400 Hz and is classed as low-consumption type, drawing 560-660 VA inrush and only 8-10 VA holding power at 68 °F (20 °C). The 190 V AC control voltage (40-400 Hz) is the coil's nominal pick-up voltage — not a universal 120 V or 240 V coil. The operational limits are 0.85-1.1 Uc at 131 °F (55 °C), meaning it reliably picks up between about 162 V and 209 V AC. Drop-out occurs between 0.35-0.55 Uc (roughly 67-105 V AC), so a brownout below that threshold will release the contactor. Inrush power of 560-660 VA at 40-400 Hz determines the peak load the control transformer or PLC output must handle during pick-up. The steady-state hold-in drops to 8-10 VA, which is what the coil draws continuously once the contactor is sealed. Coil resistance measures 45.6 Ω inrush and 1054 Ω holding at 68 °F (20 °C). Opening time is 25 ms, closing time 45 ms — these are the mechanical response times of the contactor assembly with this coil fitted. Maximum operating rate is 3600 cycles per hour at 131 °F (55 °C), which governs how fast the contactor can cycle in high-duty applications like conveyor indexing or press control. Heat dissipation runs 8.4-10.4 W, which must be accounted for in enclosure thermal calculations, especially when multiple contactors are ganged in a panel. ## Coil technology note This coil is supplied without a built-in suppressor module. For applications where transient suppression is required — such as when the coil is driven by a PLC output or solid-state relay — an external RC snubber or varistor must be added across the coil terminals to protect the switching device from inductive kickback. ## Operating environment Rated for ambient air temperatures of -5 °C to 55 °C (23-131 °F). This covers most indoor industrial panel environments but does not extend to extreme cold storage or high-heat zones near furnaces without derating.","metaTitle":"Schneider Electric LX9FH1902 TeSys F Contactor Coil, 190 V A","metaDescription":"LX9FH1902 is a TeSys F specific contactor coil, 190 V AC 40-400 Hz low consumption. Obsolete — sourced to order against RFQ. Inrush 560-660 VA, hold-in 8-10 VA.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"190 V AC 40...400 Hz","Operating Time":"25 ms opening 45 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4add2e05183d4a39ec391acad4942f08.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FH1902/tesys-f-specific-contactor-coil-190-v-ac-40-400-hz-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FH1902/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FH1902","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FH1902 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}