{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FH3202","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FH3202","canonicalUrl":"https://aoctrl.com/schneider/LX9FH3202","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FH3202","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F, specific contactor coil, LX9FH3202, 316..340 V AC 40..400 Hz, low consumption, obsolete.","salesMarkdown":"The LX9FH3202 is a specific contactor coil from the TeSys F range, designed as the control-circuit component for TeSys F contactors. It operates on a 316 to 340 V AC control circuit at 40 to 400 Hz, with a low-consumption design that draws 8 to 10 VA holding power and 560 to 660 VA inrush at 68 °F (20 °C). The coil's average resistance measures 136.1 Ω inrush and 2892 Ω holding at the same temperature. The 316 to 340 V AC control voltage range means this coil is intended for line-voltage control circuits in regions where nominal supply is 400 V three-phase, typically tapped phase-to-phase at 347 V. The 0.85 to 1.1 Uc operational limit (268 to 374 V AC at 131 °F) and 0.35 to 0.55 Uc drop-out range (110 to 187 V AC) define the voltage window for reliable pick-up and guaranteed release — critical for coordinating with undervoltage protection schemes. The opening time of 25 ms and closing time of 45 ms are fast enough for general motor switching but not for high-speed inverter bypass applications where sub-10 ms response is needed. Heat dissipation of 8.4 to 10.4 W means the coil contributes measurable thermal load inside the enclosure. In a densely packed panel, this must be factored into the thermal budget — especially if the contactor cycles frequently at the maximum rate. The coil ships without a built-in suppressor module. For inductive-load switching, an external RC snubber or varistor across the coil terminals is required to limit voltage spikes and comply with EMC directives — a standard practice for AC control circuits. As a TeSys F specific contactor coil, this part is deployed inside motor control centers and industrial control panels where TeSys F contactors are installed. It is the replaceable coil assembly for the contactor's electromagnetic drive — when the coil fails, you swap this component rather than the entire contactor.","metaTitle":"TeSys LX9FH3202 Contactor Coil, 316-340 V AC, Obsolete","metaDescription":"Obsolete TeSys F specific contactor coil LX9FH3202, 316-340 V AC 40-400 Hz low consumption. Sourced to order against RFQ. 10 Mcycles mechanical durability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"316...340 V AC 40...400 Hz","Operating Time":"25 ms opening 45 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9cdbf2f0732fb9ee49cb67d331268b55.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FH3202/specific-contactor-coil-tesys-f-316-340-v-ac-40-400-hz-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FH3202/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FH3202","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FH3202 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}