{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FJ912","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FJ912","canonicalUrl":"https://aoctrl.com/schneider/LX9FJ912","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FJ912","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, specific contactor coil LX9FJ912, 24 V DC / 27...29 V AC 40-400 Hz control circuit, 60 ms opening / 20 ms closing, 10 Mcycles mechanical durability.","salesMarkdown":"The LX9FJ912 is a specific contactor coil from the Schneider TeSys F range, designed as the replaceable magnetic coil for TeSys F contactors. It operates the contactor's armature — 60 ms to open, 20 ms to close — which governs how fast the main poles make or break the load circuit. The control circuit accepts either 24 V DC or 27...29 V AC at 40...400 Hz, making it flexible for panels with mixed control voltages. Inrush power hits 500 VA at 20 °C; holding power drops to 23 VA once the armature seals. Heat dissipation runs 11.4 to 13.9 W, so the coil contributes noticeable thermal load inside the enclosure — factor that into cabinet sizing if multiple contactors are ganged. The coil lacks a built-in suppressor module, so you'll need an external RC snubber or varistor across the coil terminals if driving it from a PLC output or electronic timer. This coil mounts directly onto the TeSys F contactor's magnet assembly — it is the replaceable element, not the full contactor. The control circuit voltage limits are 0.85...1.1 Uc for pickup at 55 °C, and dropout occurs between 0.3 and 0.5 Uc at the same temperature — useful to know when verifying hold-in on a brownout or long control-wire run.","metaTitle":"Schneider LX9FJ912 TeSys F Contactor Coil, 24 VDC / 27-29 VA","metaDescription":"Obsolete TeSys F contactor coil LX9FJ912. 24 VDC / 27-29 VAC control, 60 ms open / 20 ms close. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"24 V DC 27...29 V AC 40...400 Hz","Operating Time":"60 ms opening 20 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption DC low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cfbe10019e8731247d94ffe122fc1f64.pdf","sourceUrl":"https://www.se.com/sg/en/product/LX9FJ912/specific-contactor-coil-tesys-f-lx9fj-temperature-70-c/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FJ912/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FJ912","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FJ912 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}