{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FJ922","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FJ922","canonicalUrl":"https://aoctrl.com/schneider/LX9FJ922","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FJ922","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, specific contactor coil LX9FJ922, dual-rated 75 V DC / 80-87 V AC control circuit, without built-in suppressor module.","salesMarkdown":"The LX9FJ922 is a specific replacement coil for the TeSys F contactor range. It is a field-replaceable component, not a complete contactor — you swap the coil when the original fails or you need a different control voltage. The control circuit accepts either 75 V DC or 80 to 87 V AC at 40 to 400 Hz. That dual rating covers most 110 VAC-derived control transformers with a center tap or a dedicated 75 VDC supply. The coil holds in at 23 VA on AC; inrush hits 500 VA at 20 °C. There is no built-in suppressor module. If the contactor drives an inductive load — motor starter, heater contactor — you will need an external RC snubber or varistor across the coil terminals to protect the PLC output or relay driving it. The 60 ms opening time is typical for this frame size; the 20 ms closing time means it pulls in fast enough for most sequencing. ## Thermal and mechanical limits Heat dissipation runs 11.4 to 13.9 W depending on control voltage and duty. That is not trivial inside a sealed enclosure — check the panel temperature rise if you cluster several TeSys F contactors. That is fast enough for a repetitive pick-and-place or conveyor indexing application; for continuous high-speed counting you may need a larger frame or a dedicated DC coil variant. Because this is a specific coil for the TeSys F platform, it is not a generic substitute for other contactor families. If your BOM calls out LX9FJ922, the fit is confirmed for the TeSys F frame.","metaTitle":"Schneider LX9FJ922 TeSys F Contactor Coil, 75 VDC / 80-87 VA","metaDescription":"LX9FJ922 is an active TeSys F specific contactor coil. Dual-rated 75 V DC / 80-87 V AC control circuit. No built-in suppressor. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX9FJ922","Category":"22341-CONTACTOR,D,K,&F ACCESS","description":"specific contactor coil - TeSys F - LX9FJ - temperature < 70 °C","Operating time":"60 ms opening 20 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"11.4...13.9 W","Device short name":"LX9FJ","Inrush power in VA":"500 VA 40...400 Hz (at 68 °F (20 °C))","Control circuit type":"AC 40...400 Hz low consumption DC low consumption","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"3600 cyc/h 158 °F (70 °C)","Product or Component Type":"Specific contactor coil","[Uc] control circuit voltage":"75 V DC 80...87 V AC 40...400 Hz","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))","Hold-in power consumption in VA":"23 VA 40...400 Hz (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57c72f7f9987aeb9403efbb43dfa80c7.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FJ922/specific-contactor-coil-tesys-f-lx9fj-temperature-70-c/"},"ai":{"faq":[{"question":"What is the control voltage for this coil?","answer":"The control circuit accepts 75 V DC or 80 to 87 V AC at 40 to 400 Hz. Operational limits are 0.85 to 1.1 Uc at 55 °C; dropout occurs between 0.3 and 0.5 Uc."},{"question":"Does this coil include a built-in suppressor?","answer":"No. The coil technology is listed as without built-in suppressor module. An external RC snubber or varistor is required when switching inductive loads."},{"question":"What is the operating temperature range?","answer":"Ambient air temperature for operation is -5 to 55 °C (23 to 131 °F)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FJ922","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FJ922 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}