{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FJ924","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FJ924","canonicalUrl":"https://aoctrl.com/schneider/LX9FJ924","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FJ924","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F, specific contactor coil, LX9FJ924, 100-110 V AC 40-400 Hz / 89-99 V DC control circuit, 60 ms opening, 20 ms closing, without built-in suppressor module.","salesMarkdown":"The LX9FJ924 is a specific contactor coil from the TeSys F range, designed as the replacement coil for TeSys F contactors. It's not a universal coil — it's the dedicated magnet assembly for that frame size. The control circuit accepts 100-110 V AC at 40-400 Hz or 89-99 V DC, so it covers both common industrial control voltages without needing a separate rectifier. The coil draws 500 VA inrush at 68 °F (20 °C) across 40-400 Hz, and holds at 23 VA. That inrush figure matters for sizing the control transformer — a 500 VA surge on a marginal transformer can cause a voltage dip that prevents the contactor from pulling in. Heat dissipation runs 11.4-13.9 W, so if the coil is in a tightly packed panel, account for that thermal load. The coil ships without a built-in suppressor module; if your control circuit needs one, you'll add it externally. ## Control voltage limits and temperature range The coil operates reliably between 0.85 and 1.1 times the control voltage (Uc) at 131 °F (55 °C), and drops out between 0.3 and 0.5 Uc. That means on a 110 V AC system, it holds in down to about 93.5 V and drops out around 33-55 V — good for brownout ride-through. Ambient operating temperature is -5 to 55 °C (23-131 °F), which is standard for indoor panel environments.","metaTitle":"TeSys LX9FJ924 Specific Contactor Coil, 100-110V AC / 89-99V","metaDescription":"Obsolete TeSys F LX9FJ924 specific contactor coil. 100-110V AC 40-400 Hz / 89-99V DC control voltage. 60 ms opening, 20 ms closing. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"89...99 V DC 100...110 V AC 40...400 Hz","Operating Time":"60 ms opening 20 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption DC low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dfbebad6c529f5b1e71437653e6bd34d.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX9FJ924/specific-contactor-coil-tesys-f-lx9fj-temperature-70-c/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FJ924/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FJ924","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FJ924 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}