{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FJ926","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FJ926","canonicalUrl":"https://aoctrl.com/schneider/LX9FJ926","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FJ926","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F specific contactor coil, LX9FJ926, 110 V AC/DC low consumption, 60 ms opening / 20 ms closing, obsolete.","salesMarkdown":"The LX9FJ926 is a specific contactor coil from the TeSys F range, designed to replace the coil in a TeSys F-frame contactor. It's a service part, not a standalone component — you swap it into the contactor when the original coil fails or you need a different control voltage. Rated for 110 V AC and 110 V DC control circuits (50/60 Hz AC, low-consumption DC), it draws an inrush of 430 W at 20 °C and holds at 22 W. The coil resistance measures 32.3 Ω inrush, 302 Ω holding at 20 °C. Opening time is 60 ms, closing 20 ms — fast enough for most motor-starting and general switching duties. The control circuit accepts AC 40–400 Hz or DC low-consumption drive. The operational voltage window is 0.85 to 1.1 Uc (93.5–121 V for a 110 V coil) at 55 °C; dropout occurs between 0.3 and 0.5 Uc (33–55 V). That's a wide dropout margin — the contactor stays pulled in through a sag down to about half nominal, which is typical for industrial control. Heat dissipation runs 11.4 to 13.9 W depending on coil state. The coil has no built-in suppressor module. If your control circuit uses solid-state outputs or a PLC with sensitive electronics, you'll want to add an external RC snubber or flyback diode across the coil terminals to suppress the inductive kick when it de-energizes.","metaTitle":"TeSys LX9FJ926 Contactor Coil, 110 V AC/DC, Obsolete","metaDescription":"TeSys LX9FJ926 specific contactor coil for F-frame contactors. 110 V AC/DC control, 60 ms opening, 20 ms closing. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"110 V DC 110 V AC","Operating Time":"60 ms opening 20 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption DC low consumption","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/15f4688f4716f3a35d47f67b1eafbecc.pdf","sourceUrl":"https://www.se.com/sg/en/product/LX9FJ926/tesys-f-specific-contactor-coil-127-v-dc-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FJ926/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FJ926","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FJ926 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}