{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FK913","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FK913","canonicalUrl":"https://aoctrl.com/schneider/LX9FK913","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FK913","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, specific contactor coil LX9FK913, 30-32 V AC/DC, 60 ms opening, 20 ms closing, without built-in suppressor module.","salesMarkdown":"The LX9FK913 is a specific contactor coil from the Schneider Electric TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It operates on a control circuit voltage of 30...32 V AC or DC, with a 60 ms opening time and a 20 ms closing time — the opening speed matters for arc extinction on inductive loads, so if you're swapping a coil in a motor-starting circuit, that 60 ms is what governs contact separation. ## Control circuit and coil technology This coil is supplied without a built-in suppressor module, so you'll need to add an external RC snubber or varistor across the coil terminals if the control circuit drives inductive loads or if you're seeing noise on the PLC output. The control circuit type accepts AC 40...400 Hz or DC low consumption, meaning it works on standard 50/60 Hz line or DC supplies without derating. Inrush power hits 470 W at 20 °C, then settles to a hold-in consumption of 29 W — that inrush spike is brief but enough to sag a small 24 VDC supply if you're firing multiple coils simultaneously. ## Operating limits and durability Rated for an ambient temperature range of -5...55 °C, so it's fine inside a ventilated panel but not for direct outdoor exposure. The control voltage limits are tight: operational range is 0.85...1.1 Uc at 55 °C, and drop-out occurs between 0.3...0.5 Uc — meaning if your DC supply dips below about 9 V (on a 30 V nominal), the coil drops out and the contactor opens.","metaTitle":"TeSys LX9FK913 specific contactor coil, 30-32 V AC/DC, activ","metaDescription":"TeSys LX9FK913 specific contactor coil for TeSys F contactors. 30-32 V AC/DC control, 60 ms opening, 20 ms closing. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX9FK913","Category":"22341-CONTACTOR,D,K,&F ACCESS","description":"TeSys F - specific contactor coil","Operating time":"60 ms opening 20 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"15...18.3 W","Device short name":"LX9FK","Inrush power in W":"470 W 68 °F (20 °C))","Control circuit type":"AC 40...400 Hz low consumption DC low consumption","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"3600 cyc/h 158 °F (70 °C)","Product or Component Type":"Specific contactor coil","Inductance of closed circuit":"0.22 H","[Uc] control circuit voltage":"30...32 V DC 30...32 V AC","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))","Hold-in power consumption in W":"29 W 68 °F (20 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/efa6fad0cdc8f689d29dd67ac5e353fb.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FK913/tesys-f-specific-contactor-coil/"},"ai":{"faq":[{"question":"What is the control voltage for this coil?","answer":"The control circuit voltage is 30...32 V AC or DC. The operational limits are 0.85...1.1 Uc at 55 °C, and drop-out occurs between 0.3...0.5 Uc."},{"question":"Does this coil include a built-in suppressor module?","answer":"No, the LX9FK913 is supplied without a built-in suppressor module. An external RC snubber or varistor should be added if the control circuit drives inductive loads."},{"question":"What is the operating temperature range?","answer":"The ambient air temperature for operation is -5...55 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FK913","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FK913 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}