{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FL919","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FL919","canonicalUrl":"https://aoctrl.com/schneider/LX9FL919","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FL919","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F, specific contactor coil, LX9FL919, 52..58 V DC low consumption, obsolete.","salesMarkdown":"The LX9FL919 is a specific contactor coil from the TeSys F range, designed as the replacement coil for TeSys F contactors. It operates on a 52...58 V DC control circuit, low-consumption type, drawing 48 W hold-in power at 68 °F (20 °C) with an inrush of 733 W at the same temperature. Coil technology is without built-in suppressor module, so you'll need to add external flyback suppression (diode or RC snubber) across the coil terminals if driving from a PLC output or electronic controller. The control circuit accepts both AC 40...400 Hz and DC low-consumption drive. Opening time is 60 ms, closing time 20 ms — fast enough for general motor switching but not for high-speed synchronous transfer applications. The 5 Mcycles mechanical durability means this coil will outlast most contactor main contacts in normal cycling duty; the limiting factor in service will be the contactor's electrical life at the switched load. Heat dissipation runs 22.8...27.8 W continuous. In a dense panel with multiple TeSys F contactors side by side, that adds up — allow natural convection spacing or forced airflow to keep the ambient within the -5...55 °C operating range. Maximum operating rate is 1800 cycles/hour at 158 °F (70 °C), which is the coil's thermal limit, not the contactor's. Control voltage limits: operational range is 0.85...1.1 Uc at 131 °F (55 °C), so for a 52...58 V DC coil the pickup voltage is around 44...49 V DC minimum. Drop-out occurs at 0.3...0.5 Uc, meaning the coil releases between roughly 15.6 and 29 V DC — important to verify if your control supply has a slow decay or shared DC bus with other loads. If you're standardizing a panel design, the practical path is to evaluate the current TeSys F coil offering from the same range at the required control voltage and contactor frame size. The mechanical interface (mounting, core geometry) is consistent within the TeSys F family, but coil voltage options have shifted — verify the new order code against your contactor's catalog number before committing.","metaTitle":"TeSys LX9FL919 specific contactor coil, 52..58 V DC, obsolet","metaDescription":"TeSys F LX9FL919 specific contactor coil, 52..58 V DC low consumption. Obsolete — sourced to order against RFQ. 60 ms opening, 20 ms closing. 5 Mcycles mechanical durability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"52...58 V DC","Operating Time":"60 ms opening 20 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 40...400 Hz low consumption DC low consumption","Mechanical Life Cycles":"5 Mcycles","Main Product Or Component Type":"Specific contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/19683ca223f053e2bada619b0513b323.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX9FL919/specific-contactor-coil-tesys-f-52-58-v-dc-low-consumption/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX9FL919/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FL919","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FL919 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}