{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX9FL920","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX9FL920","canonicalUrl":"https://aoctrl.com/schneider/LX9FL920","factsUrl":"https://aoctrl.com/api/mcp/products/LX9FL920","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F, specific contactor coil, LX9FL920, 59..65 V DC low consumption, 60 ms opening / 20 ms closing, heat dissipation 22.8...27.8 W.","salesMarkdown":"The LX9FL920 is a specific contactor coil from the TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It operates on a control circuit voltage of 59...65 V DC and is classed as low consumption — meaning it draws less steady-state power than a standard AC or DC coil of the same frame size. Opening time is 60 ms, closing time is 20 ms. The coil has no built-in suppressor module, so you'll need to add an external RC snubber or flyback diode across the coil terminals if driving it from a PLC output or solid-state relay. Heat dissipation runs 22.8...27.8 W, which matters for panel thermal budgeting — especially if multiple contactors are ganged in a small enclosure. Inrush power at 20 °C is 733 W, but that's a transient; the hold-in power settles to 48 W at the same temperature. Because it's a specific coil (not a universal replacement), confirm the mating contactor frame and the control voltage range before committing the line. ## Installation and integration notes The coil accepts AC control supply from 40 to 400 Hz as well as DC, but the rated voltage range is 59...65 V DC. Operational limits are 0.85...1.1 Uc at 55 °C; dropout occurs between 0.3...0.5 Uc at the same temperature. Ambient operating temperature is -5...55 °C. That's adequate for most motor-starting and resistive-load switching applications in a standard industrial panel.","metaTitle":"TeSys LX9FL920 specific contactor coil, 59..65 V DC low cons","metaDescription":"TeSys F specific contactor coil, 59..65 V DC low consumption. Active lifecycle, sourced to order against RFQ. 60 ms opening, 20 ms closing. Heat dissipation 22.8...27.8 W.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX9FL920","Category":"22341-CONTACTOR,D,K,&F ACCESS","description":"specific contactor coil - TeSys F - 59..65 V DC - low consumption","Operating time":"60 ms opening 20 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"22.8...27.8 W","Device short name":"LX9FL","Inrush power in W":"733 W 68 °F (20 °C))","Control circuit type":"AC 40...400 Hz low consumption DC low consumption","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"1800 cyc/h 158 °F (70 °C)","Product or Component Type":"Specific contactor coil","[Uc] control circuit voltage":"59...65 V DC","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))","Hold-in power consumption in W":"48 W 68 °F (20 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/894acf991242582f39d2f0778fa06ad2.pdf","sourceUrl":"https://www.se.com/th/en/product/LX9FL920/specific-contactor-coil-tesys-f-59-65-v-dc-low-consumption/"},"ai":{"faq":[{"question":"What is the control voltage for the LX9FL920?","answer":"The control circuit voltage is 59...65 V DC. It also accepts AC supply from 40 to 400 Hz, but the rated DC range is the one to design around."},{"question":"Does the LX9FL920 include a built-in suppressor module?","answer":"No, the coil technology is listed as 'Without built-in suppressor module'. An external snubber or flyback diode must be added for inductive-load switching."},{"question":"What is the operating temperature range for this coil?","answer":"Ambient air temperature for operation is -5 to 55 °C. The maximum operating rate of 1800 cycles per hour is specified at 70 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX9FL920","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX9FL920 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}