{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM05BD28M2","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM05BD28M2","canonicalUrl":"https://aoctrl.com/schneider/LXM05BD28M2","factsUrl":"https://aoctrl.com/api/mcp/products/LXM05BD28M2","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium 05 LXM05BD28M2 motion servo drive, 2.5 kW at 4 kHz, 200–240 V single-phase supply, with integrated EMC filter, listed as obsolete.","salesMarkdown":"## What the line-side ratings mean for panel sizing The LXM05BD28M2: Line current is 23 A at 200 V and 19.2 A at 240 V — the higher draw sits at the lower supply voltage, which is the usual pattern for a single-phase rectifier input and is what the feeder breaker and branch wiring have to be sized for. Inrush current peaks at 60 A, so any upstream protective device has to ride through that surge without nuisance-tripping on the closing cycle. Power supply voltage limits are 170–264 V against a 200–240 V nominal, giving the standard ±10% / −15% tolerance band the drive tolerates before it drops out or faults on undervoltage. ## Output stage — current, switching frequency, duty Continuous output current is 15 A at the 4 kHz default and 13 A at 8 kHz — raising the switching frequency quiets the motor whine but costs roughly 13% of the continuous output current, and that thermal derating is usually the binding limit on a retrofit. The 2.5 kW nominal power rating is stated at 4 kHz, consistent with the higher of the two current figures. Transient RMS output current is 20 A for 3 seconds at both 4 kHz and 8 kHz, which covers the short-torque-boost window a servo axis typically needs during acceleration. Overvoltage category III confirms the drive is rated for fixed industrial distribution inside the panel, downstream of the building feeder. Maximum leakage current is 30 mA — that figure drives the residual-current device selection upstream, and it is the reason a 30 mA RCD on a single-phase servo feeder will nuisance-trip unless the installer picks a type that tolerates the DC component in the leakage waveform. Supply frequency is 50/60 Hz ±5%, with operating limits 47.5–63 Hz. ## I/O and bus interface on this variant The drive carries 2 safety discrete inputs and 4 logic discrete inputs — the safety pair is the hardware STO interface for the servo loop, separate from the logic-level commands. Modbus is the listed serial bus and the documentation flags no polarization impedances for Modbus on this variant, meaning the bus termination has to be supplied externally on the segment.","metaTitle":"LXM05BD28M2 Lexium 05 servo drive, 2.5 kW, obsolete","metaDescription":"Schneider LXM05BD28M2 Lexium 05 motion servo drive, 2.5 kW at 4 kHz, 200–240 V single-phase, listed as obsolete. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Drives"],"specifications":{"Line current":"23 A at 200 V 19.2 A at 240 V","Nominal power":"2.5 kW at 4 kHz","Component name":"LXM05B","Inrush current":"60 A","Output voltage":"1000...2000 m with conditions","lifecycle_stage":"current","Range of product":"Lexium 05","Supply frequency":"50/60 Hz - 5...5 %","Switching frequency":"8 kHz 4 kHz","Overvoltage category":"III","Power Supply Voltage":"200...240 V - 15...10 %","Type of polarization":"No polarization impedances for Modbus","Discrete input number":"2 safety discrete input(s) 4 logic discrete input(s)","Maximum leakage current":"30 mA","Network number of phases":"Single phase","Continuous output current":"13 A at 8 kHz 15 A at 4 kHz","Product or component type":"Motion servo drive","Power Supply Voltage Limits":"170...264 V","maximum prospective line Isc":"1 kA","transient RMS output current":"20 A at 4 kHz for 3 s 20 A at 8 kHz for 3 s","Power Supply Frequency Limits":"47.5...63 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/LXM05BD28M2/motion-servo-drive-lxm05b-2-5-kw-200-240-v-1phase-with-emc-filter/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LXM05BD28M2/alternatives.json"},"ai":{"faq":[{"question":"What is the line current of the LXM05BD28M2?","answer":"Line current is 23 A at 200 V and 19.2 A at 240 V on a single-phase supply, with a 60 A inrush on closing. The upstream feeder and branch protection have to be sized to the higher figure at the lower voltage."},{"question":"What is the nominal power rating of the LXM05BD28M2?","answer":"Nominal power is 2.5 kW at the 4 kHz switching-frequency default, with continuous output current of 15 A at 4 kHz and 13 A at 8 kHz. Running at 8 kHz trades motor noise for roughly 13% less continuous current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM05BD28M2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM05BD28M2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}