{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM05CD17M2","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM05CD17M2","canonicalUrl":"https://aoctrl.com/schneider/LXM05CD17M2","factsUrl":"https://aoctrl.com/api/mcp/products/LXM05CD17M2","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium 05 LXM05CD17M2 motion servo drive, 1.2 kW at 4 kHz, 200-240 V single-phase, 10.5 A line current at 240 V, 8 A continuous output at 8 kHz, with EMC filter.","salesMarkdown":"## Power and current at switching frequency The LXM05CD17M2: Nominal power is 1.2 kW at 4 kHz switching frequency — the rating that governs continuous motor load in a typical positioning application. At 8 kHz the continuous output current drops from 8 A to 7 A, and the transient RMS output (3 s) goes from 12 A to 11 A. The 8 kHz setting quiets the motor whine but costs about 12% of the continuous current headroom. Line current draw is 10.5 A at 240 V supply, 12.7 A at 200 V — the lower the input voltage, the higher the input current for the same output power. Input is single-phase 200-240 V, 50/60 Hz, with limits of 170-264 V and 47.5-63 Hz. Overvoltage category III, so it's designed for fixed-installation distribution panels. ## Obsolete — sourcing through surplus channels Marked obsolete by Schneider Electric. No official successor or pin-compatible replacement is recorded from the manufacturer. Available through independent surplus and broker channels; quantities are lot-specific and confirmed at RFQ. The 1 kA maximum prospective line Isc sets the SCCR for the branch circuit — the upstream protective device must be coordinated to keep fault current below this level. Inrush current is 60 A, which matters for sizing the supply contactor and transformer. ## I/O and fieldbus integration Six logic discrete inputs and one analogue input are on board — enough for limit switches, home sensor, and a speed/torque reference without an expansion module. The Modbus port has no polarization impedances fitted; if the bus is longer than a few meters, external bias resistors are needed at the master end. Maximum leakage current is 30 mA — a consideration when the drive shares a residual-current device (RCD) with other equipment; a Type B or selective RCD may be required to avoid nuisance trips. ## Altitude derating and EMC fit Output voltage derating applies above 1000 m up to 2000 m with conditions — for installations at altitude, the continuous output current must be reduced per the manufacturer's derating curve (not detailed here). The drive ships with an integrated EMC filter, which simplifies compliance to EN 61800-3 for the first environment (residential/light industrial) when installed per the manual's cable and grounding guidelines.","metaTitle":"Schneider Electric LXM05CD17M2 Lexium 05 Servo Drive, 1.2 kW","metaDescription":"Schneider Electric LXM05CD17M2 Lexium 05 servo drive, 1.2 kW at 4 kHz, 200-240 V single-phase. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Servo Drives"],"specifications":{"Line current":"10.5 A at 240 V 12.7 A at 200 V","Nominal power":"1.2 kW at 4 kHz","Component name":"LXM05C","Inrush current":"60 A","Output voltage":"1000...2000 m with conditions","lifecycle_stage":"current","Range of product":"Lexium 05","Supply frequency":"50/60 Hz - 5...5 %","Switching frequency":"8 kHz 4 kHz","Overvoltage category":"III","Power Supply Voltage":"200...240 V - 15...10 %","Type of polarization":"No polarization impedances for Modbus","Analogue input number":"1","Discrete input number":"6 logic discrete input(s)","Maximum leakage current":"30 mA","Network number of phases":"Single phase","Continuous output current":"7 A at 8 kHz 8 A at 4 kHz","Product or component type":"Motion servo drive","Power Supply Voltage Limits":"170...264 V","maximum prospective line Isc":"1 kA","transient RMS output current":"11 A at 8 kHz for 3 s 12 A at 4 kHz for 3 s","Power Supply Frequency Limits":"47.5...63 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc0211ad42725e137f86e0f1710eb923.pdf","sourceUrl":"https://www.se.com/vn/en/product/LXM05CD17M2/motion-servo-drive-lxm05c-1-2-kw-200-240-v-1phase-with-emc-filter/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LXM05CD17M2/alternatives.json"},"ai":{"faq":[{"question":"What is the line current of LXM05CD17M2?","answer":"10.5 A at 240 V supply, 12.7 A at 200 V supply. These are the RMS input currents at rated load."},{"question":"What is the nominal power of LXM05CD17M2?","answer":"1.2 kW at 4 kHz switching frequency. At 8 kHz the continuous output current derates from 8 A to 7 A."},{"question":"What compliance documentation does Schneider Electric provide for LXM05CD17M2?","answer":"The drive is part of the Lexium 05 range and ships with an integrated EMC filter. Standard compliance documentation (CE, RoHS, REACH) is available from Schneider Electric's support portal; the specific declarations for this order code are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM05CD17M2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM05CD17M2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}