{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM16DU15M2X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM16DU15M2X","canonicalUrl":"https://aoctrl.com/schneider/LXM16DU15M2X","factsUrl":"https://aoctrl.com/api/mcp/products/LXM16DU15M2X","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric LXM16DU15M2X Easy Lexium 16 motion servo drive, single-phase 200-240 V, 1.5 kW nominal power, 8 kHz switching frequency, compact housing, no EMC filter.","salesMarkdown":"## What the 1.5 kW rating means for your axis The LXM16DU15M2X delivers 1.5 kW nominal power at 220 V with an 8 kHz switching frequency — the switching rate is fixed, not adjustable, so the motor winding inductance and cable capacitance must be compatible with that carrier frequency to avoid over-heating the drive output stage. Continuous output current is 8.3 A, with a 3-second peak of 30 A at 220 V — that 3.6× overload margin handles the acceleration and deceleration transients typical of pick-and-place or indexing axes without oversizing the drive. Line current draw is 14.4 A at 144.8 % of rated load on single-phase 220 V — this is the input current the upstream branch circuit and wiring must be sized for, not the motor current. ## Single-phase supply, no EMC filter — plan the panel accordingly This drive runs on 200-240 V single-phase only — no three-phase input option. The supply voltage tolerance is -15 % to +10 % at 220 V nominal, with a line frequency range of 47.5-63 Hz. The LXM16DU15M2X ships without an internal EMC filter (per the description). An external filter must be added at the panel level to meet conducted emission limits for CE or other regulatory marks — factor the filter footprint and cost into the BOM. Maximum leakage current is 3.5 mA — this is the ground-leakage figure for sizing the upstream RCD or GFCI. Overvoltage category III means the drive is rated for fixed-installation distribution-level transients. ## Active production — BOM-fit and sourcing This is a qualified part for serial-production BOMs that need supply continuity. Part of the Easy Lexium 16 family, compact housing format — the drive is sized for DIN-rail or panel mounting in control cabinets where space is constrained. No official successor or cross-reference exists; the LXM16D short name identifies the platform.","metaTitle":"Schneider Electric LXM16DU15M2X Easy Lexium 16 Servo Drive","metaDescription":"Schneider Electric LXM16DU15M2X motion servo drive, Easy Lexium 16 series, 1.5 kW at 220 V single phase, 8 kHz switching, active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Drives"],"specifications":{"title":"LXM16DU15M2X","description":"motion servo drive, Easy Lexium 16, single phase 200...240V 1.5kW, no EMC filter","Line current":"14.4 A 144.8 % at 220 V, single phase","Nominal power":"1.5 kW at 220 V 8 kHz","Output voltage":"1000...2000 m with current derating","lifecycle_stage":"current","Continuous power":"1500 W at 220 V","Range of product":"Easy Lexium 16","Supply frequency":"50/60 Hz - 5...5 %","Device short name":"LXM16D","Network frequency":"47.5...63 Hz","Format of the drive":"Compact housing","Switching frequency":"8 kHz","Overvoltage category":"III","Supply voltage limits":"200...240 V single phase","Output current 3s peak":"30 A at 220 V","Maximum leakage current":"3.5 mA","Network number of phases":"Single phase","Continuous output current":"8.3 A","Product or component type":"Motion servo drive","[Us] rated supply voltage":"220 V (- 15...10 %) for single phase"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f474c601fda6086fe12750153e186777.pdf","sourceUrl":"https://www.se.com/sg/en/product/LXM16DU15M2X/motion-servo-drive-easy-lexium-16-single-phase-200-240v-1-5kw-no-emc-filter/"},"ai":{"faq":[{"question":"What is the line current draw of LXM16DU15M2X?","answer":"The line current is 14.4 A at 144.8 % of rated load on single-phase 220 V supply. This is the input current for sizing the branch circuit and upstream protection."},{"question":"Does LXM16DU15M2X include an internal EMC filter?","answer":"No, this variant ships without an EMC filter. An external filter must be added at the panel level to meet conducted emission compliance requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM16DU15M2X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM16DU15M2X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}