{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM16MU02M2X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM16MU02M2X","canonicalUrl":"https://aoctrl.com/schneider/LXM16MU02M2X","factsUrl":"https://aoctrl.com/api/mcp/products/LXM16MU02M2X","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric LXM16MU02M2X motion servo drive, Easy Lexium 16 series, 0.2 kW nominal power at 220 V, single-phase 200-240 V supply, 1.6 A continuous output, 8 kHz switching frequency, Modbus communication, compact housing.","salesMarkdown":"## Single-phase servo drive for light-duty positioning The LXM16MU02M2X is a 0.2 kW motion servo drive from Schneider Electric's Easy Lexium 16 series, designed for single-phase 200-240 V supply lines. It delivers 1.6 A continuous output current and can supply 7.5 A peak for 3 seconds, which covers acceleration and deceleration transients on small positioning axes. The drive draws 2.5 A line current at 220 V single phase — this is the figure to use when sizing the upstream branch circuit protection and the supply transformer for a multi-axis cabinet. ## Power stage and switching frequency Switching frequency is fixed at 8 kHz, which balances motor audible noise against thermal losses in the output stage. At this frequency the drive delivers its full 200 W continuous power at 220 V. The supply frequency tolerance is 50/60 Hz ±5 %, with the network frequency range extending from 47.5 to 63 Hz — the drive locks to the incoming line frequency within that window. ## Supply and grounding requirements Rated supply voltage is 220 V (-15 % / +10 %) single phase, with absolute limits of 200-240 V. Overvoltage category III means the drive is designed for fixed installation downstream of the building's main distribution board, not for outlet-plug connection. Maximum leakage current is 3.5 mA — this is within the threshold for standard 30 mA RCDs, but the drive should be on a dedicated circuit if multiple units share a common protective device. The drive ships as a compact housing unit with Modbus communication onboard. No EMC filter is integrated — plan for an external filter if the installation must meet conducted emission limits for the single-phase supply.","metaTitle":"Schneider LXM16MU02M2X Easy Lexium 16 Servo Drive, 0.2 kW","metaDescription":"Schneider Electric LXM16MU02M2X motion servo drive, Easy Lexium 16 series, 0.2 kW at 220 V, single-phase 200-240 V input, Modbus, active production, available","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Drives"],"specifications":{"title":"LXM16MU02M2X","description":"motion servo drive, Easy Lexium 16, single phase 200...240V 0.2kW, no EMC filter, Modbus","Line current":"2.5 A 206.1 % at 220 V, single phase","Nominal power":"0.2 kW at 220 V 8 kHz","Output voltage":"1000...2000 m with current derating","lifecycle_stage":"current","Continuous power":"200 W at 220 V","Range of product":"Easy Lexium 16","Supply frequency":"50/60 Hz - 5...5 %","Device short name":"LXM16D","Network frequency":"47.5...63 Hz","Format of the drive":"Compact housing","Switching frequency":"8 kHz","Overvoltage category":"III","Supply voltage limits":"200...240 V single phase","Output current 3s peak":"7.5 A at 220 V","Maximum leakage current":"3.5 mA","Network number of phases":"Single phase","Continuous output current":"1.6 A","Product or component type":"Motion servo drive","[Us] rated supply voltage":"220 V (- 15...10 %) for single phase"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b1d16893a2354d239eab08b3478658b.pdf","sourceUrl":"https://www.se.com/id/en/product/LXM16MU02M2X/motion-servo-drive-easy-lexium-16-single-phase-200-240v-0-2kw-no-emc-filter-modbus/"},"ai":{"faq":[{"question":"What line current does LXM16MU02M2X draw for supply sizing?","answer":"Line current is 2.5 A at 220 V single phase, measured at 206.1 % of rated load. Use this value for sizing the supply cable and protective device."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM16MU02M2X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM16MU02M2X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}