{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM26DU45M3X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM26DU45M3X","canonicalUrl":"https://aoctrl.com/schneider/LXM26DU45M3X","factsUrl":"https://aoctrl.com/api/mcp/products/LXM26DU45M3X","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric LXM26DU45M3X Easy Lexium 26 motion servo drive, three-phase 200…230 V, 4.5 kW, 22.9 A continuous output at 8 kHz, compact housing.","salesMarkdown":"## What the 4.5 kW rating means for the motor match The LXM26DU45M3X is a 4.5 kW servo drive at 220 V three-phase, switching at 8 kHz — that's the nominal motor power it's designed to drive continuously without exceeding the thermal limits of the output stage. Continuous output current is 22.9 A at that same 8 kHz switching frequency, so the drive delivers full rated torque into a motor with that current draw at the nameplate voltage. For short bursts during acceleration or deceleration, the drive can push 61 A for 3 seconds — useful for overcoming inertia on a rapid index move without oversizing the drive for the steady-state load. ## Line current and upstream protection sizing Line current at 220 V three-phase is 17.9 A at 147.1 % of rated load — that's the draw the branch circuit breaker and supply cables need to be rated for, not the motor's continuous current. Supply voltage limits are 170…255 V three-phase, 50/60 Hz ±5 %, with the network frequency window at 47.5…63 Hz — the drive tolerates a wider frequency swing than the voltage tolerance allows. Overvoltage category III means this drive is designed for fixed installation downstream of the building's main distribution board, where transient overvoltages are already clamped by upstream SPDs. ## Altitude derating and installation limits Above 1000 m the output voltage derates at 1 % per 100 m — at 2000 m the drive loses 10 % of its output voltage capability, which directly reduces the available torque at the motor shaft. Maximum leakage current is 1.55 mA — below the 3.5 mA threshold that would require a fixed RCD or a dedicated earth leakage warning label per IEC 60364. Part of the Easy Lexium 26 family, compact housing format — this is Schneider's entry-level servo drive line for basic positioning and speed control applications.","metaTitle":"Schneider LXM26DU45M3X Lexium 26 Servo Drive, 4.5 kW, 22.9 A","metaDescription":"Schneider Electric LXM26DU45M3X Easy Lexium 26 servo drive, 4.5 kW at 220 V three-phase, 22.9 A continuous output. Active production. Sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Drives"],"specifications":{"title":"LXM26DU45M3X","description":"motion servo drive - Lexium 26 - three phase 200...230 V - 4.5 kW","Line current":"17.9 A 147.1 % at 220 V, three phase","Nominal power":"4.5 kW at 220 V 8 kHz","Output voltage":"1000...2000 m 1 % per 100 m","lifecycle_stage":"current","Continuous power":"4500 W at 220 V","Range of product":"Easy Lexium 26","Supply frequency":"50/60 Hz - 5...5 %","Device short name":"LXM26D","Network frequency":"47.5...63 Hz","Format of the drive":"Compact housing","Switching frequency":"8 kHz","Overvoltage category":"III","Supply voltage limits":"170...255 V three phase","Output current 3s peak":"61 A at 220 V","Maximum leakage current":"1.55 mA","Network number of phases":"Three phase","Continuous output current":"22.9 A at 8 kHz","Product or component type":"Motion servo drive","[Us] rated supply voltage":"220 V (- 10...15 %) for three phase"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/56eb8d51ecdd0bd3979f6db90682ee0e.pdf","sourceUrl":"https://www.se.com/id/en/product/LXM26DU45M3X/motion-servo-drive-lexium-26-three-phase-200-230-v-4-5-kw/"},"ai":{"faq":[{"question":"What is the continuous output current of LXM26DU45M3X?","answer":"Continuous output current is 22.9 A at 8 kHz switching frequency, at 220 V three-phase supply. That's the thermal limit for sustained duty — the drive can deliver 61 A for 3 seconds peak for acceleration transients."},{"question":"What line current does LXM26DU45M3X draw for sizing the supply?","answer":"Line current is 17.9 A at 147.1 % of rated load at 220 V three-phase. Size the branch circuit breaker and supply cables for this draw, not the motor's continuous current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM26DU45M3X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM26DU45M3X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}