{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM32MC10N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM32MC10N4","canonicalUrl":"https://aoctrl.com/schneider/LXM32MC10N4","factsUrl":"https://aoctrl.com/api/mcp/products/LXM32MC10N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium 32 LXM32MC10N4 servo drive, 11 kW, three-phase, book format, 240 mm depth, integrated SIL 3 STO safety function, CE marked.","salesMarkdown":"## 11 kW servo drive with integrated SIL 3 STO The LXM32MC10N4 is a Lexium 32 servo drive rated 11 kW continuous at both 400 V and 480 V supply, with a 4 kHz switching frequency. It draws 23.3 A line current at 480 V under 140 % overload; without a line choke that figure climbs to 32 A at 54 % of rated voltage, and with a 0.5 mH external choke it reaches 38.1 A at 70 %. The integrated STO (safe torque off) function is rated SIL 3 per EN/IEC 61508, with a response time ≤ 5 ms on both STO_A and STO_B channels. This meets the safety integrity level required for guarding applications on servo axes without an external safety relay. ## Book format and panel integration The drive ships in a book format — 15.2 in (385 mm) high, 7.09 in (180 mm) wide, 9.4 in (240 mm) deep — designed for vertical mounting within ±10° of plumb. The integrated fan handles cooling; no derating is needed up to 1000 m altitude. Pollution degree 2 per EN/IEC 61800-5-1 and shock resistance rated 15 gn at 11 ms per EN/IEC 60028-2-27. The CN8 terminal torque spec is 33.6 lbf·in (3.8 N·m). CE marked and designed to EN/IEC 61800-3 for EMC in the drive category. The integrated EMC filter covers conducted emissions for most industrial environments without an external filter. Relative humidity class 3K3 (5 to 85 % without condensation) per IEC 60721-3-3. Supply frequency tolerance is 50/60 Hz ±5 %, with a wider network frequency range of 47.5 to 63 Hz.","metaTitle":"Schneider Electric LXM32MC10N4 Lexium 32 Servo Drive, 11 kW","metaDescription":"Schneider Electric LXM32MC10N4 Lexium 32 servo drive, 11 kW at 400/480 V, three-phase, book format. Integrated SIL 3 STO safety function. CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"9.4 in (240 mm)","Width":"7.09 in (180 mm)","Height":"15.2 in (385 mm)","Current":"23.3 A 140 % 480 V, without line choke 32 A 54 % 480 V, with external line choke 0.5 mH 38.1 A 70 % 480 V, with external line choke 0.5 mH","Frequency":"4 kHz","IP Rating":"IP20","Response Time":"<= 5 ms compliment of STO_A, compliment of STO_B","Product Status":"Active","Pollution Degree":"2 EN/IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-25 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-13...158 °F (-25...70 °C)","Discrete Output Logic":"Positive or negative DO)EN/IEC 61131-2","Main Product Or Component Type":"Motion servo drive","Ambient Air Temperature Operation":"32...122 °F (0...50 °C) UL"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,841.50 – $4,645.19","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/LXM32MC10N4/motion-servo-drive-lexium-32-100a-three-phase-supply-voltage-208-to-480v-11kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LXM32MC10N4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM32MC10N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM32MC10N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}