{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXM62DC13G21000","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXM62DC13G21000","canonicalUrl":"https://aoctrl.com/schneider/LXM62DC13G21000","factsUrl":"https://aoctrl.com/api/mcp/products/LXM62DC13G21000","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PacDrive 3 LXM62 single-axis servo drive, 24.7 kW continuous, 50 A continuous / 130 A 3s peak, STO SIL 3 PL e, SERCOS III, IP20, 270 x 89 x 310 mm.","salesMarkdown":"The LXM62DC13G21000 is a single-axis servo drive from the PacDrive 3 family, rated 24.7 kW continuous power with a continuous output current of 50 A at 4 kHz switching frequency and a 3-second peak of 130 A at 4 kHz — that peak headroom handles the acceleration transient on a high-inertia load without oversizing the continuous rating. Physical envelope is 270 mm deep by 89 mm wide by 310 mm high, IP20 rated, so it lives inside a cabinet with forced airflow — the 5 °C to 55 °C operating ambient sets the derating floor; above 55 °C the continuous current must be reduced per the manufacturer's curve. Supply is three-phase 400 V nominal (-10 % / +10 %) or three-phase 230 V, with the 50/60 Hz tolerance held to ±5 %. Overvoltage category III means it's rated for fixed-installation mains connection without external suppression. ## Safety and bus integration — STO and SERCOS III Hardware STO (safe torque off) is implemented on this drive, certified to SIL 3 per IEC 61508 and PL e per ISO 13849-1 — the safety function removes drive torque without a main contactor, which simplifies the safety circuit in a guarding application. Integrated SERCOS III communication interface handles the real-time motion bus for multi-axis synchronization; the drive also carries 2 digital inputs, 2 touch-probe inputs, and 2 digital outputs for local I/O without an extra module. The terminal blocks accept wire from 0.2 mm² up to 16 mm² depending on the connector (CN4 through CN7), with clamping torque specified at 2.5 N·m for CN1. Pollution degree 2 per IEC 61800-5-2 means it's rated for normal factory-floor environments without conductive contamination. Certification stack includes UL 508C, CSA C22.2 No 14, IEC 61800-5-1 (safety), IEC 61800-3 (EMC), IEC 62061, and ISO 13849-1/2 — the drive carries acceptance for North American and European machinery directives without an external filter for most industrial environments.","metaTitle":"Schneider Electric LXM62DC13G21000 PacDrive 3 Servo Drive","metaDescription":"Active-production LXM62DC13G21000 single-axis servo drive, 24.7 kW continuous, 50 A / 130 A peak, STO SIL 3 PL e, SERCOS III. Quoted to order against BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"270 mm","Width":"89 mm","Height":"310 mm","Frequency":"8 kHz","IP Rating":"IP20","Input Count":"2 digital 2 touch probe","Output Count":"2 digital","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-2","Temp Operating Max":"55 °C","Temp Operating Min":"5 °C","Main Product Or Component Type":"Single axis servo drive","Ambient Air Temperature Operation":"-5...55 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/LXM62DC13G21000/lxm62-single-axis-servo-drive-advanced-130a-hw-sto-sil-3-ple-acckit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LXM62DC13G21000/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXM62DC13G21000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXM62DC13G21000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}