{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LXMRSP0650200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LXMRSP0650200","canonicalUrl":"https://aoctrl.com/schneider/LXMRSP0650200","factsUrl":"https://aoctrl.com/api/mcp/products/LXMRSP0650200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Lexium SCARA robot, 4-axis, 500 mm arm reach, 200 mm vertical stroke, 6 kg payload, 2 kW, tabletop mount, IP20.","salesMarkdown":"## What LXMRSP0650200 actually is The four axes give J1 ±130°, J2 ±129°, J3 200 mm, and J4 ±360°, with the whole arm rotating through a full 360° at the base — the kinematic envelope an integrator sizes the cell around (cites:,). ## Throughput, accuracy, and where it actually fits on a line Maximum actuation speed is 7050 mm/s on the J1+J2 horizontal axes and 1100 mm/s on J3, with a J4 angular speed of 2150°/s — the cycle-time ceiling on a pick-and-place or small-parts assembly station (cites:,). Repeatability sits at ±0.02 mm on J1 and J2, ±0.01 mm on J3, and ±0.01° on J4 — tight enough for screw-driving, dispensing, and small-connector insertion without an external fixturing camera (cites:). ## Electrical envelope, EMC, and cabinet planning Mains is 170…250 V AC full-performance, with a 100…170 V AC window that derates performance by 15% — the cabinet feed needs to be confirmed against the lowest expected steady-state line voltage, not just the nominal (cites:). Peak power draw is 2 kW with a rated continuous of 0.9 kW; the upstream breaker and contactor should be sized for the 2 kW surge at acceleration, not the steady figure (cites:,). EMC hardening is 4 kV ESD and 2 kV fast-transient, ambient 0…40 °C operating, with altitude derating kicking in above 1000 m (10% at 1500 m, 20% at 2000 m) — plan the cabinet layout around that thermal envelope rather than the bare IP20 rating (cites:,). Base protection is IP20; the listed IP65 figure is reached only with the conformity kit fitted, which is the option the cell-builder needs to spec separately if the robot sits in a washdown or splash zone (cites:). ## Acoustic footprint and shop-floor reality Noise level is rated at 70 dB — quiet enough that the cell does not need an acoustic enclosure for operator comfort, but loud enough to keep a hearing-protection note in the risk assessment when several units run side by side (cites:).","metaTitle":"LXMRSP0650200 Schneider Electric SCARA Robot, 500 mm","metaDescription":"Schneider Electric LXMRSP0650200 Lexium SCARA robot, 500 mm arm, 200 mm Z, 6 kg payload, 2 kW. Active production, quoted to order against the BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"IP Rating":"IP20 / IP65","Input Voltage":"170...250 V AC without derating 100...170 V AC with derating of 15%","Product Status":"Active","Temp Storage Max":"60 °C","Temp Storage Min":"-20 °C","Operating Position":"Rotational 360°","Temp Operating Max":"60 °C","Temp Operating Min":"-20 °C","Temperature Storage":"-4...140 °F (-20...60 °C)","Main Product Or Component Type":"SCARA robot","Ambient Air Temperature Operation":"32...104 °F (0...40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a26788d941da9a290827789726aee57.pdf","sourceUrl":"https://www.se.com/be/en/product/LXMRSP0650200/scara-robot-lexium-scara-500mm-arm-200mm/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LXMRSP0650200/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LXMRSP0650200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LXMRSP0650200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}