{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"M9U21103","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"M9U21103","canonicalUrl":"https://aoctrl.com/schneider/M9U21103","factsUrl":"https://aoctrl.com/api/mcp/products/M9U21103","rawCanonicalId":null},"summary":{"shortDescription":"MULTI9 C60H-DC 3A C 250V-DC MCB|MULTI9 C60H-DC 3A C 250V-DC MCB","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray","Depth":"2.9 in (73 mm)","Range":"Multi9","Width":"0.7 in (18 mm)","Height":"3.2 in (81 mm)","Category":"US10DE200948","Standards":"EN/IEC 60947-2 GB 14048.2 UL 1077","Curve code":"C","9 Mm Pitches":"2","Control Type":"Toggle","Network type":"DC","Product name":"Multi9 C60H-DC","Mounting Mode":"Clip-on","Tropicalisation":"2 IEC 60068-2 2 GB 14048.2","lifecycle_stage":"unknown","Local signalling":"ON/OFF indication","Mounting Support":"DIN rail","Pollution degree":"3 EN/IEC 60947-2","Breaking capacity":"10 kA Icu 220 V DC EN/IEC 60947-2 6 kA Icu 250 V DC EN/IEC 60947-2 20 kA Icu 110 V DC EN/IEC 60947-2 5 kA AIR 12...250 V DC UL 1077 10 kA Icu 220 V DC GB 14048.2 6 kA Icu 250 V DC GB 14048.2 20 kA Icu 110 V DC GB 14048.2","Device short name":"C60H-DC","Poles description":"1P","Relative humidity":"95 % 131 °F (55 °C)","Tightening torque":"22.1 lbf.in (2.5 N.m) top or bottom","Device Application":"Distribution","Line Rated Current":"3 A 77 °F (25 °C) EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A EN/IEC 60947-2","Electrical durability":"3000 cycles 250 V DC L/R = 2 ms 6000 cycles 250 V DC","Mechanical durability":"20000 cycles","Nbr. of units in pkg.":"1","Wire stripping length":"0.6 in (14 mm) for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom) 0.002...0.04 in² (1...25 mm²) AWG 18...AWG 4) - rigid stranded Tunnel type terminal top or bottom) 0.002...0.02 in² (1...16 mm²) AWG 18...AWG 6) - flexible Tunnel type terminal top or bottom) 0.002...0.02 in² (1...16 mm²) AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal top or bottom) - 2 0.002...0.02 in² (1...10 mm²) AWG 18...AWG 8) - rigid stranded Tunnel type terminal top or bottom) - 2 0.002...0.02 in² (1...10 mm²) AWG 18...AWG 8) - flexible Tunnel type terminal top or bottom) - 2 0.002...0.02 in² (1...10 mm²) AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal top or bottom) - 3 0.002 in² (1 mm²) AWG 18) - flexible stranded","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"7...10 x In DC","Earth-leakage protection":"Without","Provision for padlocking":"Padlockable","Number of protected poles":"1","Product or Component Type":"Miniature circuit-breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V DC EN/IEC 60947-2","[Ue] rated operational voltage":"250 V DC 110 V DC 220 V DC","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"7.5 kA 75 % EN/IEC 60947-2 - 220 V DC 4.5 kA 75 % EN/IEC 60947-2 - 250 V DC 15 kA 75 % EN/IEC 60947-2 - 110 V DC 7.5 kA 75 % GB 14048.2 - 220 V DC 4.5 kA 75 % GB 14048.2 - 250 V DC 15 kA 75 % GB 14048.2 - 110 V DC","[Uimp] rated impulse withstand voltage":"6 kVEN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$106.09 – $180.41","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a74a9693c3dbc12039df077df4029f68.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/M9U21103/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/M9U21103","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/M9U21103 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}