{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"METSEEM3561","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"METSEEM3561","canonicalUrl":"https://aoctrl.com/schneider/METSEEM3561","factsUrl":"https://aoctrl.com/api/mcp/products/METSEEM3561","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerLogic EM3561 energy meter, METSEEM3561, Class 0.2S accuracy, 90...347 V, 5...32000 A, BACnet MS/TP, DIN rail, dark grey.","salesMarkdown":"The Schneider Electric METSEEM3561 is a PowerLogic EM3561 energy meter, part of the EM3500 range, designed for sub-billing and partial metering in commercial and industrial panels. It mounts on a DIN rail and accepts low-voltage current transformer inputs at 0.333 V or 1 V, covering a measurement range of 5...32000 A. Rated supply voltage is 90...347 V AC, 50/60 Hz, 3P + N. The backlit LCD display shows five digits of active, reactive, and apparent power per phase and total, plus power factor, voltage, current, and frequency. ## Accuracy and compliance Power and energy accuracy is ±0.2 %, with a Class 0.2S rating per IEC 62053-22 and ANSI C12.20. That means the meter holds its calibration within 0.2 % of reading across the specified current and power factor range — suitable for tenant sub-metering where billing-grade precision is required. The enclosure carries UL 508, CSA C22.2 No 14-05, and IEC 61010-1 approvals, covering North American and international panel installations. ## Communications and integration A screw-terminal RS485 port supports BACnet MS/TP at 9600 to 115200 baud with automatic baud detection. The meter logs energy consumption, records peak demand power, and can synchronise demand intervals via communication or a fixed/rolling block. Tamperproof settings are protected by an access code. Local signalling includes a red LED for threshold reached and a green flashing LED for output signal.","metaTitle":"Schneider Electric METSEEM3561 PowerLogic EM3561 Energy Mete","metaDescription":"Schneider Electric METSEEM3561 PowerLogic EM3561 energy meter. Class 0.2S accuracy, 90...347 V, 5...32000 A, BACnet MS/TP, DIN rail. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Unclassified"],"specifications":{"Color":"Dark grey","Depth":"2.3 in (59 mm)","Range":"PowerLogic","Width":"4.2 in (107 mm)","title":"METSEEM3561","Height":"3.6 in (91 mm)","Category":"US10PL109798","Standards":"UL 508 CSA C22.2 No 14-05 IEC 61010-1","Input Type":"Low voltage current transformer 0.333 V or 1 V","description":"PowerLogic EM3500 DIN rail meter - BACnet without logging - current transformer","9 Mm Pitches":"12","Display Type":"Backlit LCD","Metering type":"Peak demand power PM, QM, SM Current I1, I2, I3, Iavg Demand power P, Q, S Voltage U21, U32, U13, V1, V2, V3","Mounting Mode":"Clip-on By screws","Rated voltage":"90...347 V","Accuracy class":"Class 0.2S power IEC 62053-22 Class 0.2S energy IEC 62053-22 Class 0.2S power ANSI C12.20 Class 0.2S energy ANSI C12.20","Data recording":"Energy consumption logs","Display digits":"5","Technology Type":"Electronic","lifecycle_stage":"current","Demand intervals":"External synchronisation to communication Fixed or rolling block","Local signalling":"Red LED threshold reached Green flashing LED output signal","Mounting Support":"DIN rail","Range Of Product":"PowerLogic EM3500","Device short name":"EM3561","Network frequency":"60 Hz 50 Hz","Poles description":"3P + N","Relative humidity":"0...95 %","Ride-through time":"100 ms 120 V AC","Device Application":"Sub billing Partial meter","Measurement current":"5...32000 A","Type of measurement":"Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency","Measurement accuracy":"Power +/- 0.2 % Energy +/- 0.2 %","Communication Service":"Total cumulated active energy Total cumulated energy","Information displayed":"Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage","Nbr. of units in pkg.":"1","Power consumption in W":"3 W 300 V","Power consumption in VA":"5 VA 347 V AC between phase and neutral) 5 VA 600 V AC between phases)","Tamperproof of settings":"Protected by access code","Product or Component Type":"Energy meter","Communication port support":"Screw terminal block RS485","Communication port protocol":"BACnet MS/TP 9600 bauds...115200 bauds (automatic detection) - 2-wire","Number Of Accumulator Inputs":"2 pulse","[Ue] rated operational voltage":"90...347 V AC 50/60 Hz between phase and neutral UL 156...600 V AC 50/60 Hz between phases UL 90...300 V AC 50/60 Hz between phase and neutral CE 125...300 V DC","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient air temperature for operation":"-22...158 °F (-30...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/METSEEM3561/powerlogic-em3500-din-rail-meter-bacnet-without-logging-current-transformer/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for METSEEM3561?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to METSEEM3561 in this component family?","answer":"Within the PowerLogic EM3500 range, the EM3561 is the variant with BACnet MS/TP communication. Other EM3500 meters differ by protocol (Modbus, pulse) or display options, but share the same DIN-rail footprint, voltage range, and CT input type. For a direct BACnet replacement, order the METSEEM3561."},{"question":"What is METSEEM3561's listed color (Dark grey) on this component line?","answer":"The METSEEM3561 is listed in Dark grey."},{"question":"What is METSEEM3561's listed depth (2.3 in (59 mm)) on this component line?","answer":"The depth is 2.3 in (59 mm)."},{"question":"What compliance documentation does this brand provide for METSEEM3561 (RoHS, REACH, UL, IEC)?","answer":"The METSEEM3561 carries UL 508, CSA C22.2 No 14-05, and IEC 61010-1 approvals. RoHS and REACH compliance documentation is available from Schneider Electric upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/METSEEM3561","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/METSEEM3561 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}