{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"METSEION92040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"METSEION92040","canonicalUrl":"https://aoctrl.com/schneider/METSEION92040","factsUrl":"https://aoctrl.com/api/mcp/products/METSEION92040","rawCanonicalId":null},"summary":{"shortDescription":"Power Meter, PowerLogic, DIN Mount, 192mm, 90-480VAC, 110-480VDC|Power Meter, PowerLogic ION 9000, DIN Mount, 192 mm Display, Color Touchscreen, 90 - 480 Volt AC, 110 - 480 Volt DC","salesMarkdown":null,"metaTitle":"Schneider METSEION92040 ION9000 Power Meter","metaDescription":"Schneider METSEION92040 PowerLogic ION9000 power meter, 192 mm color touchscreen, panel mount, 90–480 V AC, 110–480 V DC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"5.3 in (135.3 mm)","Range":"PowerLogic","Width":"6.3 in (160 mm)","Height":"6.3 in (160 mm)","Category":"US10PM109761","Standards":"ANSI C12.20 ANSI C37.90.1 IEC 61000-4-15 IEC 61000-4-30 IEC 61010-1 IEC 61326-1 IEC 61557-12 IEC 61850 IEC 62052-11 IEC 62052-31 IEC 62053-22 IEC 62053-23 IEC 62053-24 IEC 62586 UL 61010-1","Input Type":"Voltage (impedance 5 MOhm) External CT (impedance 0.3 mOhm)5 x","Display Type":"Remote LCD display Colour touchscreen","Product name":"PowerLogic ION9000","Web services":"Viewing of captured waveform Web page Pass/fail report for IEEE 519 Pass/fail report for EN 50160 ITIC (CBEMA) curve SEMI curve NEMA motor derating curve Alarm notification by e-mail TLS 1.2 Push historical data via mail","Cybersecurity":"Syslog protocol support Robust security logs Port hardening Enable/disable communication ports Hardware metrology lock","Metering type":"Demand current I1, I2, I3, I4, I5 Peak demand currents Demand power P, Q, S Peak demand power PM, QM, SM Calculated active and reactive energy (+/- W.h, +/- VAR.h)","Port Ethernet":"10/100BASE-TX 2 RJ45","Sampling rate":"1024 samples/cycle","Accuracy class":"Class 0.1S active energy IEC 62053-22 Class 0.1 active energy IEC 61557-12 Class 0.1 active energy ANSI C12.20 Class 0.5S reactive energy IEC 62053-24 Class 0.1 current IEC 61557-12 Class 0.1 voltage IEC 61557-12 Class 0.1 active power IEC 61557-12 Class 0.5 power factor IEC 61557-12","Data recording":"Time stamping Min/max of instantaneous values User-definable data logs Continuous logging or snapshot Trending/forecasting Event logs Alarm logs Configuration change Power outage User login/logout Data logs GPS synchronisation Sequence of event recording","Market Segment":"Data center Healthcare Semiconductor Pharmaceutical Chemical Energy Mining","Quality labels":"ISO 9001 ISO 14000","Memory capacity":"2 GB","Type Of Network":"3P + N + E","lifecycle_stage":"current","Ethernet service":"DHCP client Device Profile Web Services (DPWS) Rapid Scanning Tree Protocol (RSTP) FTP/HTTP/HTTPS","Mounting support":"DIN rail meter device Door cut-out remote display","Number of inputs":"8 digital 30 V AC/60 V DC","Device short name":"ION92040","Isolation voltage":"III400...690 V conforming to EN 61010-1:ed. 3 III347...600 V conforming to UL 61010-1:ed. 3 III347...600 V conforming to CSA C22.2 No 61010-1:ed. 3","Network Frequency":"50 Hz 60 Hz","Number of Outputs":"4 digital 2 form C relay output","Relative humidity":"5...95 %","Ride-through time":"100 ms 6 cycles at 60 Hz 120 V AC typical 400 ms 24 cycles at 60 Hz 240 V AC typical 1200 ms 72 cycles at 60 Hz 480 V AC typical","Device Application":"Power monitoring WAGES metering Net metering Medium voltage High voltage","Display Resolution":"800 x 480 pixels","Line Rated Current":"1 A 5 A","Operating altitude":"0...9842.52 ft (0...3000 m)","Provided Equipment":"Remote display Remote display adapter Mounting instructions Mounting Hardware","Measurement current":"0.01...20 A","Measurement voltage":"57...400 V AC 42...69 Hz between phase and neutral 100...690 V AC 42...69 Hz between phases","Type of measurement":"Voltage sags and swells Current sags and swells Voltage Current Frequency Active and reactive power total Apparent power total Active and reactive power per phase Apparent power per phase Power factor total Power factor per phase Active and reactive energy Apparent energy Harmonic distortion (I THD & U THD)","Degree of protection":"UL type 12, front","Measurement accuracy":"Voltage +/- 0.1 % Current +/- 0.1 %","Communication Service":"Compliant reports Power quality summary Energy report EcoStruxure Power Events Analysis SMTP e-mail notification SNMP","Communication gateway":"Ethernet/serial","Installation category":"III","Nbr. of units in pkg.":"1","Power quality analysis":"EN 50160 compliance checking IEEE 519 harmonic limit IEC 61000-4-30 class A compliance reporting IEEE 519 compliance reporting waveform capture total demand distortion total harmonic distortion up to the 63rd harmonic up to the 127th harmonic with software disturbance direction detection dip, swell and transient half cycle data acquisition transient detection (20 µs)","IP degree of protection":"IP65 front: IP30 rear:","Power consumption in VA":"38 VA 480 V AC","Tamperproof of settings":"Protected by sealable cover","Product or Component Type":"Energy and power quality meter","[Us] rated supply voltage":"90...480 V AC 45...66 Hz +/- 10 % 90...120 V AC 400 Hz +/- 10 % 110...480 V DC +/- 10 %","Communication port support":"2 RS485 removable screw terminal block","Communication port protocol":"Modbus RTU 2400...115200 bps - 2-wire ION 2400...115200 bps - 2-wire DNP3 2400...115200 bps - 2-wire Modbus TCP 10/100 Mbit/s ION TCP 10/100 Mbit/s DNP3 TCP 10/100 Mbit/s IEC 61850 Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s DHCP DNS DLMS","Electrical insulation class":"Class III EN/IEC 62052-11","Frequency measurement range":"20...450 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 62052-11 EMC immunity conforming to IEC 61326-1 EMC immunity conforming to IEC 61000-6-5 Electrostatic discharge immunity test conforming to IEC 61000-4-2 Immunity to radiated fields conforming to IEC 61000-4-3 Immunity to fast transients conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Immunity to conducted disturbances conforming to IEC 61000-4-6 Immunity to magnetic fields at network frequency conforming to IEC 61000-4-8 Immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Immunity to impulse waves conforming to IEC 61000-4-12 Conducted and radiated emissions conforming to EN 55011 Conducted and radiated emissions class B conforming to EN 55032 Conducted and radiated emissions class B conforming to FCC part 15 Conducted and radiated emissions class B conforming to ICES-003 Surge withstand conforming to ANSI C37.90.1 Surge withstand conforming to IEEE C37.90.1","Time synchronisation protocol":"GPS IRIG-B NTP SNTP PTP","Maximum power consumption in VA":"80 VA 480 V AC","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5a95e389c93008cd571b069971480d0e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/METSEION92040/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/METSEION92040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/METSEION92040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}