{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"METSEPM5580","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"METSEPM5580","canonicalUrl":"https://aoctrl.com/schneider/METSEPM5580","factsUrl":"https://aoctrl.com/api/mcp/products/METSEPM5580","rawCanonicalId":null},"summary":{"shortDescription":"Square D METSEPM5580 Pm5580 Panel Mount Lvdc Auxiliary|Square D METSEPM5580 Pm5580, Panel Mount, Lvdc Auxiliary","salesMarkdown":null,"metaTitle":"METSEPM5580 - Schneider Electric","metaDescription":"Square D METSEPM5580 Pm5580 Panel Mount Lvdc Auxiliary|Square D METSEPM5580 Pm5580, Panel Mount, Lvdc Auxiliary","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"72 mm","Range":"PowerLogic","Width":"96 mm","Height":"96 mm","Standards":"EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015","Display type":"Monochrome graphic LCD","Product name":"PowerLogic PM5000","Web services":"Alarm notification by e-mail Web server Diagnostic via predefined web pages Real time viewing of data","Metering type":"Measured neutral current Calculated ground current","Mounting mode":"Flush-mounted","Sampling rate":"128 samples/cycle","Accuracy class":"Class 0.2S active energy conforming to IEC 62053-22","Data recording":"Event logs Maintenance logs Min/max of instantaneous values Data logs Alarm logs Time stamping","Supply Voltage":"24 V DC","Memory capacity":"1.1 MB","Type Of Network":"3P + N 3P 1P + N","lifecycle_stage":"current","Ethernet service":"SNTP client SNMP-Traps","Mounting support":"Framework","Number of inputs":"4 digital","Pollution degree":"2","Device short name":"PM5580","Network frequency":"60 Hz 50 Hz","Number of outputs":"2 digital","Relative humidity":"5...95 % at 50 °C non-condensing","Ride-through time":"35 ms 120 V AC typical 129 ms 230 V AC typical 50 ms 125 V DC typical","Device application":"Gateway WAGES metering Power monitoring Multi-tariff","Display resolution":"128 x 128 pixels","Operating altitude":"<= 3000 m","[In] rated current":"1 A 5 A","Analogue input type":"Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm)","Measurement current":"50...10000 mA","Measurement voltage":"20...400 V AC 45...65 Hz between phase and neutral 20...828 V AC 45...65 Hz between phases","Type of measurement":"Current Voltage Frequency Power factor Energy Active and reactive power","Measurement accuracy":"Apparent power +/- 0.5 % Frequency +/- 0.05 % Active energy +/- 0.2 % Reactive energy +/- 1 % Active power +/- 0.2 % Voltage +/- 0.1 % Power factor +/- 0.005 Current +/- 0.15 % Reactive power +/- 1 %","Communication gateway":"Ethernet/serial","Information displayed":"Tariff (8)","Power quality analysis":"up to the 63rd harmonic","Connections - terminals":"Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 RS485 link: screw terminal block4 Digital input: screw terminal block8 Digital output: screw terminal block4 Ethernet network: RJ45 connector2","IP degree of protection":"IP54 display: conforming to IEC 60529 IP30 rear: conforming to IEC 60529","Product or component type":"Power meter","Communication port support":"RS485 ETHERNET","Communication port protocol":"Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V JBUS Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V Ethernet Modbus TCP/IP daisy chain BACnet IP DNP3 over ethernet","Frequency measurement range":"45...65 Hz","Electromagnetic compatibility":"Limits for harmonic current emissions class A conforming to IEC 61000-3-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency level 4 conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022 Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Surge immunity test level 4 conforming to IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Maximum power consumption in VA":"16 VA at 480 V","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fef3580df0d13e89d7fb05d981d37fa7.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/METSEPM5580/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/METSEPM5580","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/METSEPM5580 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}