{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGF36700","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGF36700","canonicalUrl":"https://aoctrl.com/schneider/MGF36700","factsUrl":"https://aoctrl.com/api/mcp/products/MGF36700","rawCanonicalId":null},"summary":{"shortDescription":"Square D MGF36700 Molded Case Circuit Breaker 600V 700A|Square D MGF36700 Molded Case Circuit Breaker 600V 700A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Black","Depth":"8.05 in (204.47 mm)","Range":"PowerPact","Width":"8.27 in (210.06 mm)","Height":"12.86 in (326.64 mm)","Category":"US10DE201205","AWG gauge":"3 x AWG 3/0...3 x 500 kcmil aluminium/copper","Standards":"UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2","Control Type":"Operating handle","Product name":"PowerPact M","Mounting mode":"Unit mount busbar)","Quality labels":"CE","Trip unit name":"ET 1.0","Number of Poles":"3P","Number of slots":"2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 voltage release MN or MX plug-in)","lifecycle_stage":"unknown","Local signalling":"1 trip indicator green)","Mounting Support":"Busbar","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Breaking capacity":"AIR 65 kA 240 V AC 50/60 Hz UL 489 AIR 35 kA 480 V AC 50/60 Hz UL 489 AIR 18 kA 600 V AC 50/60 Hz UL 489 Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2","Network Frequency":"50/60 Hz","Tightening torque":"442.5 lbf.in (50 N.m) 0.1...0.4 in² (95...240 mm²) (3 x AWG 3/0...3 x 500 kcmil)","Device Application":"Distribution","Line Rated Current":"700 A","Operating altitude":"< 6561.68 ft (2000 m) without derating 13123.36 ft (4000 m) with derating","Terminal identifier":"AL800M23K","Trip unit technology":"Electronic, basic, ET 1.0,","Utilisation category":"Category A","Electrical connection":"Busbar connection, line Busbar connection, load","Nbr. of units in pkg.":"1","Breaking capacity code":"G","IP degree of protection":"IP40","Continuous current rating":"80 %","Magnetic tripping current":"1400...7000 A","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes IEC 60947-2","Circuit breaker application":"HACR rated","Power wire stripping length":"1.0 in (25 mm)","[Ui] rated insulation voltage":"750 V IEC 60947-2","[Ue] rated operational voltage":"600 V AC 50/60 Hz UL 489","Long time pick-up adjustment range":"300...800 A","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"25 kA 240 V AC 50/60 Hz IEC 60947-2 20 kA 380/415 V AC 50/60 Hz IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e48fea84f0607bb60f235afa76589bf9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/MGF36700/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGF36700","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGF36700 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}