{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19714","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19714","canonicalUrl":"https://aoctrl.com/schneider/MGN19714","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19714","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19714, 4P, 16 A, 30 mA earth leakage, C-curve, 6 kA breaking capacity, DIN rail clip-on.","salesMarkdown":"It combines a 16 A thermal-magnetic MCB (C-curve, 5–10× In magnetic trip) with integrated 30 mA earth-leakage protection on all protected poles, in a single DIN-rail module. The clip-on mounting and 72 mm width (8 × 9 mm pitches) let it snap directly into a distribution board alongside other Acti9 devices — no extra wiring for the RCD element. Rated 16 A at 380–415 V AC, 50 Hz, with a 6 kA breaking capacity (Icn and Icu) per EN/IEC 61009-2-1 and EN/IEC 60947-2. Local signalling (ON, OFF, fault trip) and a contact-position indicator give a visual read on the toggle state without needing to test the circuit — useful during panel commissioning or fault-finding when the door is open. Clip-on DIN rail mounting, 72 mm wide (8 pitches). Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible copper on top and bottom; strip length 12 mm, tighten to 2 N·m. The 4-pole unit occupies the full width — no half-module savings here, but the integrated earth-leakage saves the space of a separate RCD downstream. IP20 on the front (finger-safe) and IP40 inside the modular enclosure — fine for a dry distribution board, not for washdown areas. Designed and certified to EN/IEC 61009-2-1 (RCBO product standard) and EN/IEC 60947-2 (for the 6 kA Icu rating). The 8/20 µs impulse withstand of 250 A per the same standard means it survives surge events common in AC networks without nuisance tripping. Suitability for isolation is marked — the toggle provides visible break confirmation for safe isolation during maintenance. Mechanical durability rated at 20,000 cycles, electrical at 10,000 cycles — typical for a distribution-grade RCBO. The toggle is non-padlockable, so if lockout/tagout is required at the device level, a separate lockable isolator upstream is needed.","metaTitle":"MGN19714 Acti9 DCP Vigi RCBO 16A 30mA 4P C-curve","metaDescription":"MGN19714 Acti9 DCP Vigi RCBO, 16 A rated, 30 mA earth leakage, 4P, C-curve, 6 kA breaking capacity, DIN rail mount. Current lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"72 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP N Vigi","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"4","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 4.5 kA 75 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d8c0607bdf27604ffb73615e26534844.pdf","sourceUrl":"https://www.se.com/nl/en/product/MGN19714/acti9-dcp-n-vigi-rcbo-4p-16a-c-curve-6000a-6ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19714/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN19714 and get a price?","answer":"MGN19714 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing — no published stock level is maintained on this listing."},{"question":"What is the closest alternative to MGN19714 in the Acti9 family?","answer":"Within the Acti9 DCP Vigi range, the closest alternative would differ by rated current (e.g., a 10 A or 20 A variant) or by earth-leakage sensitivity (e.g., 100 mA instead of 30 mA). No pin-compatible direct substitute exists — the 16 A, 30 mA, 4P, C-curve combination is specific to this order code. If the BOM allows a parametric change, a different Acti9 DCP Vigi order code with matching poles and curve can be sourced; otherwise this is the exact fit."},{"question":"What compliance documentation does Schneider provide for MGN19714?","answer":"The MGN19714 is certified to EN/IEC 61009-2-1 and EN/IEC 60947-2. Standard documentation includes the declaration of conformity (CE), the product datasheet, and installation instructions. RoHS and REACH compliance is standard for the Acti9 range, though the specific declaration should be requested at quote time if required for your quality documentation package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19714","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19714 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}