{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19716","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19716","canonicalUrl":"https://aoctrl.com/schneider/MGN19716","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19716","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi, RCBO, 4P, 25 A, C-curve, 30 mA, 6 kA, 4-module wide.","salesMarkdown":"The MGN19716 is a Schneider Electric Acti9 DCP Vigi RCBO — a residual current breaker with overcurrent protection, combining a 25 A thermal-magnetic MCB (C-curve, magnetic trip 5–10× In) and a 30 mA earth-leakage module in a single 4-module-wide DIN-rail unit. The 6 kA breaking capacity (Icn at 380–415 V AC per EN/IEC 61009-2-1, Icu per EN/IEC 60947-2) is sized for final sub-distribution boards in residential and light commercial panels — adequate for most socket-outlet and lighting circuits, but check selectivity with upstream devices if you're on a high-fault network. The integrated 30 mA earth-leakage protection covers the standard personnel-protection threshold, and the C-curve handles moderate inrush from small motor loads or capacitor banks without nuisance tripping. Clip-on mounting on standard DIN rail. The 4P unit occupies 72 mm width. IP20 on the body, IP40 inside a modular enclosure. The 85 mm height and 76 mm depth fit standard consumer-unit and sub-board enclosures. Tropicalisation class 2 and 95 % RH at 55 °C mean it holds up in warm, humid environments — think plant rooms or outdoor-rated cabinets with condensation management. Listed as current production (active lifecycle stage). The Acti9 platform is Schneider's standard final-distribution range across EMEA and Asia-Pacific, so the MGN19716 is a mainstream line item. Designed and certified to EN/IEC 61009-2-1 (RCBO product standard) and EN/IEC 60947-2 (for the 6 kA Icu rating). The 8/20 µs impulse withstand of 250 A confirms electromagnetic compatibility per the same standard. The toggle provides local signalling: ON, OFF, and fault-trip positions are visible on the front face. Contact position indicator confirms isolation status.","metaTitle":"MGN19716 Acti9 DCP Vigi RCBO, 25 A C-curve 30 mA, 6 kA","metaDescription":"Schneider Electric MGN19716 Acti9 DCP Vigi RCBO, 25 A rated, C-curve, 30 mA earth leakage, 6 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"72 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP N Vigi","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"25 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"4","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 4.5 kA 75 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/MGN19716/acti9-dcp-n-vigi-rcbo-4p-25a-c-curve-6000a-6ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19716/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for MGN19716?","answer":"The part carries EN/IEC 61009-2-1 and EN/IEC 60947-2 certification. RoHS and REACH declarations are standard for the Acti9 range, though specific document packages (declaration of conformity, CE/UKCA) are issued per batch — request them with your RFQ if needed for your quality-doc control."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19716","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19716 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}