{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19747","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19747","canonicalUrl":"https://aoctrl.com/schneider/MGN19747","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19747","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19747, 32 A rated, 30 mA earth-leakage, curve B, 4P, 6 kA breaking capacity, DIN-rail clip-on.","salesMarkdown":"## What this RCBO does on the panel The MGN19747 is a 4-pole residual current breaker with overcurrent protection (RCBO) from the Acti9 DCP Vigi range, rated at 32 A with a 30 mA earth-leakage sensitivity and a B-curve magnetic trip (3–5 × In). The 6 kA breaking capacity (Icn at 380–415 V AC, 50 Hz, per EN/IEC 61009-2-1) is sized for residential and light commercial sub-distribution where fault levels stay under that threshold. The integrated earth-leakage block saves a separate RCD module and one wiring step — a space and labour win on a multi-way board. 32 A rated current (In) with thermal-magnetic trip — the thermal element handles sustained overloads, the magnetic element clears short-circuits above 3–5 × In. For a 32 A circuit, that means the RCBO will hold a 32 A continuous load and trip on a sustained overload above that, while the magnetic trip will clear a hard fault somewhere between 96 A and 160 A. The 30 mA earth-leakage sensitivity is the standard for personal protection against indirect contact in TN and TT systems. Breaking capacity of 6 kA Icn at 380–415 V AC per EN/IEC 61009-2-1, with an Icu of 6 kA per EN/IEC 60947-2. If your site study shows a higher fault level, step up to a 10 kA rated device. ## Integration notes The IP20 finger-safe front and IP40 modular enclosure mean it is suited for enclosed distribution boards only — not for wet or outdoor locations without a weatherproof cabinet. Local signalling shows ON, OFF, and fault trip via the toggle position. The contact position indicator confirms isolation status. Not padlockable, so if lockout/tagout is required, plan for a separate lockable isolator upstream.","metaTitle":"MGN19747 Acti9 DCP Vigi RCBO, 32 A, 30 mA, Curve B, 4P","metaDescription":"MGN19747 Acti9 DCP Vigi RCBO, 32 A rated current, 30 mA earth-leakage sensitivity, curve B, 4 poles, 6 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"72 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP N Vigi","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"4","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 4.5 kA 75 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/MGN19747/acti9-dcp-n-vigi-rcbo-4p-32a-b-curve-6000a-6ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19747/alternatives.json"},"ai":{"faq":[{"question":"Who supplies MGN19747 and how is it quoted for volume purchases?","answer":"MGN19747 is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What is the closest alternative to MGN19747 in the Acti9 range?","answer":"Within the Acti9 DCP Vigi family, the closest alternative would be a different current rating or pole count — for example, a 2P version at 16 A. The MGN19747 itself is a 4P 32 A B-curve 30 mA unit; any substitution must match the poles, In, curve, and earth-leakage sensitivity for the circuit."},{"question":"What is MGN19747's listed depth?","answer":"The MGN19747 has a depth of 76 mm."},{"question":"What is MGN19747's listed range?","answer":"The MGN19747 belongs to the Acti9 range, specifically the Acti9 DCP Vigi series."},{"question":"What compliance documentation does Schneider provide for MGN19747?","answer":"The MGN19747 is certified to EN/IEC 61009-2-1 and EN/IEC 60947-2. The IP ratings (IP20, IP40) are per IEC 60529. For RoHS, REACH, and UL documentation, refer to the manufacturer's product compliance page — those declarations are not in this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19747","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19747 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}