{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19752","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19752","canonicalUrl":"https://aoctrl.com/schneider/MGN19752","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19752","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19752, 10 A, 30 mA earth leakage, C-curve, 2-pole, 10 kA breaking capacity, DIN rail clip-on.","salesMarkdown":"The MGN19752 is a 2-pole residual current breaker with overcurrent protection (RCBO) from the Schneider Electric Acti9 DCP Vigi range, combining a 10 A thermal-magnetic C-curve MCB with integrated 30 mA earth-leakage protection in a single 36 mm wide DIN-rail module. The 10 kA breaking capacity (Icn at 220-240 V AC, 50 Hz) per EN/IEC 61009-2-1 and 10 kA Icu per EN/IEC 60947-2 gives it enough fault-clearing headroom for most residential and light commercial distribution boards without forcing an upstream breaker upgrade. The 30 mA earth-leakage sensitivity is the standard for personal protection against indirect contact in IEC 60364 installations — it's what you'd specify for socket-outlet circuits or general-purpose final subcircuits where the fault path could go through a person. Integrated earth leakage means you don't need a separate RCD module upstream or downstream; the RCBO handles both overcurrent and ground-fault in one device, which saves a DIN position and simplifies wiring. The thermal-magnetic trip technology is field-proven and unaffected by harmonics that can confuse electronic trip units on some VFD-fed circuits. Clip-on mounting to DIN rail, no screws needed for the rail attachment — push on until the latch clicks. Tunnel-type terminals top and bottom accept 1 to 35 mm² rigid or 1 to 25 mm² flexible; strip 12 mm and tighten to 2 N·m. The 76 mm depth means it sits flush with other Acti9 devices, so the gland plate clearance you already have for a 4-module board is fine. IP20 on the body (fingertip-safe), IP40 inside a modular enclosure — standard for distribution boards, not for washdown zones. Non-padlockable, so if your site requires lockout provisions, plan for a separate hasp on the board door or a padlockable cover. Local signalling (ON, OFF, fault trip) and a contact position indicator let you verify state without a meter — helpful during fault isolation when the line electrician needs to confirm the RCBO has actually opened. The tropicalisation class 2 rating means it has passed damp-heat cyclic testing (95% RH at 55 °C) per IEC 60068-2-30 — suitable for coastal or high-humidity installations without derating. Limitation class 2 (energy-limiting) per IEC 60898-1 means it restricts let-through energy under fault conditions, which helps with downstream coordination. The 8/20 µs impulse withstand of 250 A per EN/IEC 61009-2-1 confirms it handles surge currents from switching transients or nearby lightning without nuisance tripping. RoHS and REACH compliance documentation is available from the manufacturer; CE marking applies for EU markets.","metaTitle":"MGN19752 Acti9 DCP Vigi RCBO, 10 A, 30 mA, C-curve, 2P","metaDescription":"MGN19752 Acti9 DCP Vigi RCBO, 10 A rated, 30 mA earth leakage, C-curve, 2-pole, 10 kA breaking capacity. DIN rail mount. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7bd17aefb9df89d5cbfeab3f855b6ed0.pdf","sourceUrl":"https://www.se.com/nl/en/product/MGN19752/acti9-dcp-h-vigi-rcbo-2p-10a-c-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19752/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN19752?","answer":"The MGN19752 has a 10 kA Icn at 220-240 V AC 50 Hz per EN/IEC 61009-2-1 and a 10 kA Icu at the same voltage per EN/IEC 60947-2. This is sufficient for most residential and light commercial distribution boards."},{"question":"What is the earth leakage sensitivity of MGN19752?","answer":"The MGN19752 has an integrated 30 mA earth-leakage protection, which is the standard sensitivity for personal protection against indirect contact in IEC 60364 installations."},{"question":"What terminals does MGN19752 use and what wire sizes does it accept?","answer":"The MGN19752 uses tunnel-type terminals top and bottom, accepting 1 to 35 mm² rigid or 1 to 25 mm² flexible conductors. Strip length is 12 mm and tightening torque is 2 N·m."},{"question":"Where can I buy MGN19752 and how is it quoted?","answer":"The MGN19752 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19752","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19752 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}