{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19753","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19753","canonicalUrl":"https://aoctrl.com/schneider/MGN19753","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19753","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19753, 2P, 13 A rated, 30 mA earth leakage, C-curve, 10 kA breaking capacity, DIN rail mount, IP20.","salesMarkdown":"It protects a 13 A final circuit against overload, short-circuit, and earth leakage in one unit, saving a DIN rail position compared to a separate MCB + RCCB pair. Breaking capacity is 10 kA Icn / Icu at 220–240 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2. The thermal-magnetic trip unit gives you the standard dual-response: thermal for sustained overloads, magnetic for fast short-circuit clearing. The 76 mm depth and 85 mm height fit standard distribution board envelopes. Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; strip 12 mm and torque to 2 N·m. IP20 finger-safe terminals with IP40 protection inside the modular enclosure. Local signalling shows ON, OFF, and fault trip status — useful for quick fault isolation without a multimeter. The toggle control is the standard actuator; the device is not padlockable, so lockout/tagout requires a separate hasp over the toggle or a downstream isolator.","metaTitle":"MGN19753 Acti9 DCP Vigi RCBO, 13 A, 30 mA, C-Curve, 10 kA","metaDescription":"MGN19753 Acti9 DCP Vigi RCBO by Schneider Electric. 13 A rated, 30 mA earth leakage, C-curve, 10 kA breaking capacity. 2P, DIN rail mount. Current production. Sourced to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0c85b78ab235f4e5a60fc0f1b9a68c0d.pdf","sourceUrl":"https://www.se.com/sg/en/product/MGN19753/acti9-dcp-h-vigi-rcbo-2p-13a-c-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19753/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN19753?","answer":"10 kA Icn / Icu at 220–240 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2."},{"question":"What is the earth-leakage sensitivity of this RCBO?","answer":"30 mA — the standard threshold for personal protection against direct contact."},{"question":"Where can I buy MGN19753 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance standards does MGN19753 meet?","answer":"Certified to EN/IEC 61009-2-1 and EN/IEC 60947-2 for breaking capacity. IP20 per IEC 60529, IP40 in modular enclosure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19753","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19753 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}