{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19754","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19754","canonicalUrl":"https://aoctrl.com/schneider/MGN19754","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19754","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi, RCBO, 2P, 16 A, C-curve, 30 mA, 10 kA, DIN rail clip-on, grey.","salesMarkdown":"It carries a 16 A rated current on a C-curve (magnetic trip 5–10× In) and integrates 30 mA earth-leakage protection, so one device covers both overcurrent and ground-fault protection for a final subcircuit. The 10 kA breaking capacity at 230/240 V AC (Icn per EN/IEC 61009-2-1) is sized for standard distribution boards in residential and light commercial panels — not for high-fault industrial switchgear, but adequate for the Acti9 board it clips into. What sets the DCP Vigi apart from a separate MCB + RCCD pair is the thermal-magnetic trip and the residual-current sense share a single housing and a common mechanism. That saves one DIN module (2P vs 4P for discrete devices) and eliminates the risk of an uncoordinated trip between two separate units. The 30 mA sensitivity is the standard for personnel protection (shock risk) per IEC 60364, not equipment-protection levels like 100 or 300 mA. If the circuit needs selectivity with downstream 10 mA RCDs, the 30 mA is the upstream choice — but for a final subcircuit feeding socket outlets or lighting, 30 mA is the default. Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible, with a 2 N·m tightening torque and 12 mm strip length. IP20 on the body, IP40 inside a modular enclosure. The toggle indicates ON, OFF, and fault-trip positions; the unit is non-padlockable, so if lockout/tagout is required, the upstream isolating switch or a padlockable MCB must be used.","metaTitle":"Schneider Electric MGN19754 Acti9 DCP Vigi RCBO, 16 A, 30 mA","metaDescription":"Schneider Electric MGN19754 Acti9 DCP Vigi RCBO, 16 A rated, 30 mA earth leakage, 10 kA breaking capacity, 2P, C-curve. DIN rail mount. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d3c4c76738a6fe13f56bae4165a21f52.pdf","sourceUrl":"https://www.se.com/sg/en/product/MGN19754/acti9-dcp-h-vigi-rcbo-2p-16a-c-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19754/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN19754 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"What is the closest alternative to MGN19754 in the Acti9 family?","answer":"Within the same Acti9 DCP Vigi family, the only difference is the rated current and sensitivity — the MGN19754 is a 16 A, 30 mA variant. A 10 A or 20 A version with the same 30 mA sensitivity would be a different order code but identical form factor and function."},{"question":"What is MGN19754's depth?","answer":"76 mm, with a height of 85 mm and width of 36 mm (4 x 9 mm pitches)."},{"question":"What compliance documentation does Schneider provide for MGN19754?","answer":"The device is certified to EN/IEC 61009-2-1 (RCBO standard) and EN/IEC 60947-2 (for the 10 kA Icu breaking capacity). Schneider typically provides CE, UKCA, and EAC declarations, plus RoHS/REACH compliance data on request through the distributor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19754","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19754 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}