{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19755","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19755","canonicalUrl":"https://aoctrl.com/schneider/MGN19755","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19755","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, 2P, 20 A rated, 30 mA earth leakage, C-curve, 10 kA breaking capacity, DIN rail clip-on.","salesMarkdown":"The Schneider Electric MGN19755 is a 2-pole residual current breaker with overcurrent protection (RCBO) from the Acti9 DCP Vigi range, combining a 20 A thermal-magnetic MCB with integrated 30 mA earth-leakage protection in a single DIN-rail module. Breaking capacity is 10 kA Icn / Icu at 220–240 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2, meaning it can safely interrupt a fault current up to 10 kA without welding its contacts or cascading failure upstream — adequate for most TN and TT systems where the prospective short-circuit current at the board stays under that threshold. Clip-on mounting to a 35 mm DIN rail, 4 × 9 mm pitches wide (36 mm), occupying two modular spaces in a distribution board — standard for a 2P RCBO in the Acti9 family. Tunnel terminals accept 1 to 35 mm² rigid or 1 to 25 mm² flexible cable; strip length 12 mm, tightening torque 2 N·m. IP20 finger-safe (IP40 in modular enclosure) — suitable for enclosed panel installation, not for outdoor or washdown exposure. The paperwork — CE, EN/IEC standards compliance, and manufacturer traceability — is clean for import clearance under HS code 8536.30 (apparatus for protecting electrical circuits).","metaTitle":"MGN19755 Acti9 DCP Vigi RCBO, 20 A, 30 mA, C-curve","metaDescription":"Schneider Electric MGN19755 Acti9 DCP Vigi RCBO, 20 A rated, 30 mA earth leakage, C-curve, 10 kA breaking capacity, 2P, DIN rail. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"20 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6df7c048b1fe4db66eaf3d763bfa76ba.pdf","sourceUrl":"https://www.se.com/nl/en/product/MGN19755/acti9-dcp-h-vigi-rcbo-2p-20a-c-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19755/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN19755?","answer":"10 kA Icn / Icu at 220–240 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2 — sufficient for most commercial and light industrial TN/TT distribution boards."},{"question":"Where can I buy MGN19755 and what is the lead time?","answer":"Sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time. Submit an RFQ for a landed-cost estimate (DDP terms available)."},{"question":"What compliance documentation does Schneider provide for MGN19755?","answer":"The RCBO is certified to EN/IEC 61009-2-1 and EN/IEC 60947-2, carries CE marking, and is manufactured under Schneider Electric's ISO 9001 quality system — documentation for RoHS and REACH compliance is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19755","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19755 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}