{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19757","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19757","canonicalUrl":"https://aoctrl.com/schneider/MGN19757","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19757","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19757, 2P, 32 A, 30 mA, C-curve, 10 kA, DIN rail.","salesMarkdown":"## Device overview and key ratings The Schneider Electric MGN19757 is a 2-pole residual current breaker with overcurrent protection (RCBO) from the Acti9 DCP Vigi range, combining a 32 A thermal-magnetic MCB with integrated 30 mA earth-leakage protection in a single 36 mm wide DIN-rail module. Rated 32 A with a C-curve magnetic trip threshold of 5 to 10 times In, so it handles moderate inrush from motor starters or lighting banks without nuisance tripping, while still clearing short circuits up to 10 kA at 230 V AC per EN/IEC 61009-2-1. The integrated 30 mA residual current element covers personnel protection (additional shock-hazard mitigation) and disconnects both poles on a fault, as evidenced by the two protected poles and earth-leakage sensitivity rating. ## Installation and panel integration Tunnel-type terminals accept 1 to 35 mm² rigid or 1 to 25 mm² flexible cable; strip 12 mm and tighten to 2 N·m. IP20 finger-safe on the front face; IP40 within a modular enclosure per IEC 60529. Local signalling via toggle position shows ON, OFF, or fault-trip state; the contact-position indicator confirms isolation status per the suitability-for-isolation declaration.","metaTitle":"Schneider Electric MGN19757 Acti9 DCP Vigi RCBO, 32 A, 30 mA","metaDescription":"Schneider Electric MGN19757 Acti9 DCP Vigi RCBO, 32 A rated, 30 mA earth leakage, C-curve, 10 kA breaking capacity, 2P, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ec65b8b62c7d6605bbb6d1f618c6e357.pdf","sourceUrl":"https://www.se.com/nl/en/product/MGN19757/acti9-dcp-h-vigi-rcbo-2p-32a-c-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19757/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for MGN19757?","answer":"Submit an RFQ through this listing; the part is sourced to order via independent distribution, and pricing and stock levels are confirmed at quote time."},{"question":"What is MGN19757's listed range (Acti9) on this component line?","answer":"The MGN19757 belongs to the Schneider Electric Acti9 range, specifically the DCP Vigi sub-family of RCBOs designed for distribution applications."},{"question":"What compliance documentation does this brand provide for MGN19757 (RoHS, REACH, UL, IEC)?","answer":"The MGN19757 is designed and tested to EN/IEC 61009-2-1 and EN/IEC 60947-2 standards for breaking capacity and impulse withstand. The IP ratings conform to IEC 60529. For RoHS/REACH declarations, refer to the manufacturer's compliance documentation available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19757","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19757 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}