{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19764","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19764","canonicalUrl":"https://aoctrl.com/schneider/MGN19764","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19764","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19764, 2P, 16 A rated, 30 mA earth leakage, curve B, 10 kA breaking capacity, clip-on DIN rail.","salesMarkdown":"The Schneider Electric MGN19764 is an Acti9 DCP Vigi RCBO — a combined residual current breaker with overcurrent protection (RCBO) in a 2-pole, 16 A rated, 30 mA earth leakage, curve B configuration. It clips onto a DIN rail, takes 4 module pitches (36 mm wide), and is rated to break 10 kA at 220-240 V AC per EN/IEC 61009-2-1. The thermal-magnetic trip unit handles overload and short-circuit; the integrated 30 mA earth-leakage sensor covers ground faults. Curve B means the magnetic trip fires at 3 to 5 times In — 48 to 80 A for this 16 A unit. That's the right curve for resistive loads and general-purpose circuits with short cable runs where inrush is low. It's not meant for motor or transformer starting where you'd need curve C or D. The 30 mA earth-leakage sensitivity is the standard for socket-outlet circuits and general protection against indirect contact. It's fast enough to protect people but not so sensitive that nuisance tripping from normal cable capacitance becomes a problem. At 4 modules wide (36 mm), it fits a standard DIN-rail enclosure. The toggle gives local ON/OFF/fault-trip indication, and the contact position indicator confirms isolation visually.","metaTitle":"MGN19764 Acti9 RCBO, 16 A, 30 mA, 10 kA, 2P","metaDescription":"MGN19764 Acti9 DCP Vigi RCBO, 16 A rated, 30 mA earth leakage, 10 kA breaking capacity, 2P, curve B. EN/IEC 61009-2-1. Clip-on DIN rail. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f7833f3d1de2f978479ddff5b97246a8.pdf","sourceUrl":"https://www.se.com/sg/en/product/MGN19764/acti9-dcp-h-vigi-rcbo-2p-16a-b-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19764/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN19764?","answer":"The MGN19764 has a breaking capacity of 10 kA Icn at 220-240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1, and 10 kA Icu at the same voltage per EN/IEC 60947-2."},{"question":"Where can I buy MGN19764?","answer":"The MGN19764 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is MGN19764's listed depth?","answer":"The MGN19764 has a depth of 76 mm."},{"question":"What is MGN19764's listed range?","answer":"The MGN19764 belongs to the Schneider Acti9 range, specifically the Acti9 DCP Vigi series of RCBOs."},{"question":"What standards does MGN19764 comply with?","answer":"The MGN19764 complies with EN/IEC 61009-2-1 (RCBO standard) and EN/IEC 60947-2 (for the breaking capacity rating). It also meets IEC 60529 for IP20/IP40 protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19764","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19764 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}