{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19766","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19766","canonicalUrl":"https://aoctrl.com/schneider/MGN19766","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19766","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, MGN19766, 25 A, 30 mA, curve B, 2-pole, 10 kA, DIN rail.","salesMarkdown":"It protects a 25 A circuit against overloads, short-circuits, and earth faults at 30 mA sensitivity, all in one DIN-rail module. The 30 mA earth-leakage threshold provides personal protection against direct contact, meeting the standard requirement for socket-outlet circuits in most IEC-based installations. Breaking capacity is 10 kA Icn / Icu at 220–240 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2. The thermal-magnetic trip unit gives you both overload protection (thermal bimetal) and short-circuit protection (magnetic solenoid) in one mechanism. Local signalling shows ON, OFF, and fault trip status directly on the toggle, so a quick visual scan of the panel tells you which circuit tripped on earth fault vs overload. IP20 on the terminals, IP40 inside the modular enclosure, so it's suited for clean, dry indoor distribution boards.","metaTitle":"MGN19766 Acti9 DCP Vigi RCBO, 25 A, 30 mA, Curve B, 2P","metaDescription":"MGN19766 Acti9 DCP Vigi RCBO, 25 A rated, 30 mA earth leakage, curve B, 2-pole, 10 kA breaking capacity. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"25 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4933e84f6cbf957e97ba9199795627c8.pdf","sourceUrl":"https://www.se.com/sg/en/product/MGN19766/acti9-dcp-h-vigi-rcbo-2p-25a-b-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19766/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN19766?","answer":"The MGN19766 has a breaking capacity of 10 kA Icn / Icu at 220–240 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2."},{"question":"What does the 30 mA earth leakage sensitivity mean?","answer":"The 30 mA sensitivity provides personal protection against direct contact with live parts — it's the standard threshold for socket-outlet circuits in residential and commercial installations per IEC 60364."},{"question":"Where can I buy MGN19766 and get current pricing?","answer":"We source the MGN19766 to order against an RFQ through independent distribution. Submit a request for quote and we'll confirm availability and current pricing at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19766","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19766 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}