{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19767","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19767","canonicalUrl":"https://aoctrl.com/schneider/MGN19767","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19767","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi, RCBO, 2P, 32 A, B-curve, 30 mA earth leakage, 10 kA breaking capacity, DIN rail clip-on, grey.","salesMarkdown":"The Schneider Electric MGN19767 is an Acti9 DCP Vigi residual current breaker with overcurrent protection (RCBO) — a 2-pole device that combines thermal-magnetic overcurrent protection (B-curve, 32 A rated current) with integrated 30 mA earth-leakage protection in a single 36 mm wide module. The B-curve magnetic tripping threshold (3...5 x In) means it responds quickly to moderate overloads, making it a typical choice for general-purpose distribution circuits in residential or light commercial final subcircuits where cable protection and personnel shock protection are both required. Breaking capacity: 10 kA Icn / Icu at 220...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1 and EN/IEC 60947-2. Earth-leakage sensitivity: 30 mA, integrated. This is the standard threshold for personnel protection against indirect contact (touch voltage). The RCBO trips when leakage to earth exceeds 30 mA, which is below the threshold for ventricular fibrillation. The 8/20 µs impulse withstand of 250 A means it resists nuisance tripping from lightning surges or switching transients common in industrial environments. IP20 (device) / IP40 (modular enclosure) per IEC 60529. IP20 means finger-safe — no ingress protection against water, so it belongs inside a cabinet or distribution board, not in a wet area. IP40 on the enclosure side means protection against tools and small wires (1 mm) but still no water. For washdown zones, you'd need an IP65-rated enclosure around it. The tunnel-type terminals accept 1...35 mm² rigid or 1...25 mm² flexible copper; strip length 12 mm, tighten to 2 N.m. That wire range covers most final circuit cable sizes up to 6 mm² (10 AWG) comfortably, and the tunnel terminal is a standard cage clamp — no special tooling. The toggle control gives ON/OFF/fault trip local signalling, and the contact position indicator confirms isolation status. Non-padlockable, so if lockout/tagout is required, you'll need a separate lockable isolator upstream or a padlockable accessory.","metaTitle":"MGN19767 Acti9 DCP Vigi RCBO, 2P 32A B-curve 30mA, 10kA","metaDescription":"MGN19767 Acti9 DCP Vigi RCBO, 2-pole 32A B-curve, 30mA earth leakage, 10kA breaking capacity. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ab30e317487a6b5a6de75bd137fa09ea.pdf","sourceUrl":"https://www.se.com/nl/en/product/MGN19767/acti9-dcp-h-vigi-rcbo-2p-32a-b-curve-10000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19767/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN19767 and how do I get a price?","answer":"The MGN19767 is sourced and quoted to order against an RFQ through independent distribution. Submit a request with your quantity and target delivery window; availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to MGN19767 in this component family?","answer":"Within the Acti9 DCP Vigi family, the closest sibling is the same 2P form factor with a different current rating or curve code — for example, a 16 A or 40 A version, or a C-curve variant. The physical footprint (36 mm wide, DIN rail clip-on) and terminal layout are identical across the family, so swapping the rating or curve does not change the wiring or panel space."},{"question":"What is MGN19767's listed depth (76 mm) on this component line?","answer":"The MGN19767 has a depth of 76 mm, a height of 85 mm, and a width of 36 mm (4 x 9 mm pitches). That depth is standard for Acti9 RCBOs and fits most DIN-rail enclosures with a minimum internal depth of 80 mm."},{"question":"What is MGN19767's listed range (Acti9) on this component line?","answer":"The MGN19767 belongs to the Schneider Electric Acti9 range, which is the current-generation modular DIN-rail distribution system for final circuits. The Acti9 DCP Vigi sub-family specifically covers RCBOs with integrated earth-leakage protection."},{"question":"What compliance documentation does this brand provide for MGN19767 (RoHS, REACH, UL, IEC)?","answer":"The MGN19767 is certified to EN/IEC 61009-2-1 and EN/IEC 60947-2 for breaking capacity and performance. The IP ratings are per IEC 60529. Schneider Electric typically provides RoHS and REACH declarations for Acti9 products; confirm specific document availability at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19767","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19767 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}