{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN19772","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN19772","canonicalUrl":"https://aoctrl.com/schneider/MGN19772","factsUrl":"https://aoctrl.com/api/mcp/products/MGN19772","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, 3P, 10 A, C-curve, 30 mA earth-leakage sensitivity, 10 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"The MGN19772 is a Schneider Electric Acti9 DCP Vigi residual current breaker with overcurrent protection (RCBO) — a single device combining a 10 A thermal-magnetic MCB (C-curve) with a 30 mA earth-leakage module, all in a 3-pole, clip-on DIN-rail package. It's built to EN/IEC 61009-2-1 and EN/IEC 60947-2, with a 10 kA breaking capacity at 220–240 V AC, 50 Hz. That 30 mA sensitivity means it protects against lethal shock in final circuits — standard for socket outlets and wet-area subcircuits where the code demands both overcurrent and residual-current protection in one unit. Rated 10 A continuous, 10 kA breaking capacity under EN/IEC 60947-2; the Icn rating under EN/IEC 61009-2-1 is 6000 A. The 30 mA earth-leakage threshold is the standard for personal protection in most residential and commercial final circuits. Thermal-magnetic trip technology gives you the bimetal overload curve plus a solenoid for short-circuit — no electronics to fail. The RCBO format saves a module width compared to a separate MCB + RCCB pair: 6 × 9 mm pitches (54 mm wide). Clip it onto a DIN rail (mounting support: DIN rail per). Wire stripping length: 12 mm. IP20 on the body, IP40 inside a modular enclosure — fine for dry indoor panels. Tropicalisation class 2 means it handles 95 % RH at 55 °C without derating. Local signalling shows ON, OFF, and fault trip via a toggle and a contact position indicator. Non-padlockable, so if your site requires lockout, plan for an external lockable isolator upstream.","metaTitle":"MGN19772 Acti9 DCP Vigi RCBO, 3P 10A C-curve 30mA 10kA","metaDescription":"MGN19772 Acti9 DCP Vigi RCBO, 3P, 10 A, C-curve, 30 mA earth leakage, 10 kA breaking capacity. Active production. Order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"54 mm","Colour":"Grey","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"DCP N Vigi","Network frequency":"50 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/MGN19772/acti9-dcp-n-vigi-rcbo-3p-10a-c-curve-6000a-10ka-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN19772/alternatives.json"},"ai":{"faq":[{"question":"What is MGN19772's listed range (Acti9) on this component line?","answer":"It belongs to the Schneider Electric Acti9 range, specifically the Acti9 DCP Vigi sub-family. The device short name is DCP N Vigi."},{"question":"What compliance documentation does this brand provide for MGN19772 (RoHS, REACH, UL, IEC)?","answer":"The part is certified to EN/IEC 61009-2-1 and EN/IEC 60947-2. The evidence does not list RoHS, REACH, or UL marks; for those declarations, request them with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN19772","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN19772 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}