{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN25145","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN25145","canonicalUrl":"https://aoctrl.com/schneider/MGN25145","factsUrl":"https://aoctrl.com/api/mcp/products/MGN25145","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN25145 miniature circuit breaker, 4-pole, D-curve, 16 A rated current, 30 kA breaking capacity at 240 V AC.","salesMarkdown":"The MGN25145 is a C60H miniature circuit breaker from the Multi9 range, a 4-pole (4P) thermal-magnetic unit with a D-curve and a 16 A rated current at 50 °C per EN/IEC 60947-2. The 16 A rating at 50 °C gives you the full current capacity in a warm panel; no derate guesswork. Breaking capacity is 30 kA Icu at 240 V AC, 15 kA at 415 V, and 10 kA at 440 V — all phase-to-phase per EN/IEC 60947-2. Occupies 8 x 9 mm pitches (72 mm wide), 81 mm tall, 73 mm deep. Strip length is 14 mm.","metaTitle":"MGN25145 C60H MCB, 4P D16, 30 kA, Multi9","metaDescription":"MGN25145 C60H miniature circuit breaker, 4-pole, D-curve, 16 A, 30 kA breaking capacity. Active production. Sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"16 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/MGN25145/c60-circuit-breaker-c60h-4p-16a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN25145/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for MGN25145?","answer":"The MGN25145 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at the time of quote."},{"question":"What is the breaking capacity of MGN25145?","answer":"The MGN25145 has a breaking capacity of 30 kA Icu at 240 V AC, 15 kA at 415 V AC, and 10 kA at 440 V AC, all phase-to-phase per EN/IEC 60947-2."},{"question":"What does the D-curve mean on this breaker?","answer":"The D-curve magnetic trip is set at 12 x In (±20 %), which allows it to handle high inrush currents from motor, transformer, or lighting ballast loads without nuisance tripping."},{"question":"What standards does MGN25145 comply with?","answer":"The MGN25145 is designed and tested to EN/IEC 60947-2, the standard for low-voltage circuit breakers used in industrial applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN25145","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN25145 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}