{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60534","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60534","canonicalUrl":"https://aoctrl.com/schneider/MGN60534","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60534","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 series, MGN60534 miniature circuit breaker, 3-pole, 6 A rated current, D curve, 20 kA breaking capacity at 240 V AC, 35 mm DIN rail mount.","salesMarkdown":"The MGN60534 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, rated 6 A at 50 °C per EN/IEC 60947-2. The 3-pole configuration (3P) handles three-phase AC networks at 50/60 Hz, with a rated operational voltage of 440 V AC phase-to-phase. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V — all conforming to EN/IEC 60947-2. For a panel fed from a 240 V service with available fault current up to 20 kA, this MCB provides full selectivity headroom. Snaps onto 35 mm symmetrical DIN rail (EN 60715). At 6 modules wide (9 mm pitches = 6), it occupies 54 mm of rail space — standard for a 3-pole C60N. IP20 finger-safe terminals suit enclosed panel installation.","metaTitle":"MGN60534 C60N MCB, 6 A D Curve, 3P, 20 kA","metaDescription":"MGN60534 Schneider C60N MCB, 6 A rated, D curve, 3-pole, 20 kA breaking capacity at 240 V. EN/IEC 60947-2. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"6 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c04fc467222d4fc45931828f9d3cd593.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60534/c60-circuit-breaker-c60n-3p-6a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60534/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60534 and how do I get a price?","answer":"The MGN60534 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest alternative to MGN60534 in the C60 family?","answer":"Within the C60N range, the closest alternative would be a different current rating or curve code — the MGN60534 is a 6 A D-curve 3P unit. If your load requires a C curve or a higher ampacity, the C60N series offers those variants with the same breaking capacity and footprint. There is no pin-compatible substitute from another manufacturer that matches the Multi9 form factor and D-curve characteristic exactly."},{"question":"What compliance documentation does MGN60534 carry?","answer":"The MGN60534 is certified to EN/IEC 60947-2, with pollution degree 3 and suitability for isolation. It carries CE marking as standard for the European market. Specific RoHS/REACH declarations are available from Schneider Electric's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60534","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60534 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}