{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60536","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60536","canonicalUrl":"https://aoctrl.com/schneider/MGN60536","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60536","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 series, MGN60536, 3-pole D-curve miniature circuit breaker, 16 A rated, 20 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"## Panel-builder commissioning notes The MGN60536 is a C60N miniature circuit breaker from the Multi9 range, a 3-pole unit with a D-curve thermal-magnetic trip set at 16 A. It is rated for distribution duty under EN/IEC 60947-2, Category A, meaning it is not intended for motor switching but for cable and equipment protection in final subcircuits. The 20 kA Icu at 240 V AC phase-to-phase gives it a high fault-clearing ceiling for a 3-module-wide (54 mm) DIN-rail device; the service breaking capacity Ics is 75 % of that figure (15 kA at 240 V), so it can reclose after a fault at that level without replacement. The D-curve magnetic trip operates at 12 x In ±20 %, which suits loads with a high inrush — small transformers, power supplies, or lighting ballasts — where a C-curve would nuisance-trip. The 54 mm width occupies 6 x 9 mm pitches. IP20 finger-safe terminals are standard for enclosed panel use. The toggle provides local ON/OFF indication and a contact position indicator confirms isolation status — the breaker is certified for isolation duty per EN/IEC 60947-2.","metaTitle":"MGN60536 C60N MCB, 3P D-Curve 16A, 20kA, Multi9","metaDescription":"MGN60536 C60N miniature circuit breaker, 3-pole, D-curve, 16 A rated, 20 kA breaking capacity at 240 V. Active production. Sourced to order against RFQ. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"16 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5abdaab755c0e3d4d278e2644b0933df.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60536/c60-circuit-breaker-c60n-3p-16a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60536/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of MGN60536?","answer":"It is a 3-pole D-curve MCB rated 16 A at 50 °C, with a breaking capacity of 20 kA Icu at 240 V AC and 10 kA at 415 V AC, conforming to EN/IEC 60947-2."},{"question":"What is the D-curve magnetic trip threshold?","answer":"The magnetic trip operates at 12 x In ±20 %, meaning it will trip instantaneously between roughly 15.4 A and 23 A for a 16 A breaker."},{"question":"Where can I buy MGN60536?","answer":"The MGN60536 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60536","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60536 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}