{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60537","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60537","canonicalUrl":"https://aoctrl.com/schneider/MGN60537","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60537","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 series, MGN60537 miniature circuit breaker, 3-pole, 20 A rated, D-curve, 10 kA Icu at 415 V AC, thermal-magnetic trip.","salesMarkdown":"The MGN60537 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C per EN/IEC 60947-2. Three protected poles, 440 V AC maximum operational voltage. Thermal-magnetic trip unit gives both overload (thermal bimetal) and short-circuit (solenoid) protection in one package. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V — all per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of Icu at each voltage level: 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. That 75 % Ics/Icu ratio means the breaker can be reclosed after clearing a fault at those levels without immediate replacement, which matters for uptime in distribution panels where fault currents are known and coordinated. Snaps onto 35 mm symmetrical DIN rail (EN 60715). Occupies 6 x 9 mm pitches = 54 mm width. Tightening torque 2 N·m on the power circuit; strip length 14 mm. IP20 finger-safe front.","metaTitle":"MGN60537 C60N MCB, 20A 3P D-Curve, 10kA at 415V","metaDescription":"MGN60537 Schneider C60N MCB, 20A rated, 3-pole, D-curve, 10kA breaking at 415V AC. Active production. Sourced to order against RFQ. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"20 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51942f8bd0f2acc043e86587fbec1cf1.pdf","sourceUrl":"https://www.se.com/th/en/product/MGN60537/c60-circuit-breaker-c60n-3p-20a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60537/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60537 at 415 V?","answer":"10 kA Icu at 415 V AC 50/60 Hz phase-to-phase, with an Ics of 7.5 kA (75 %), both per EN/IEC 60947-2."},{"question":"What is the closest alternative to MGN60537 in the C60 family?","answer":"Within the C60 range, the C60H (higher breaking) and C60L (lower breaking) are the main siblings. The C60N at 10 kA/415 V sits between them. A C60H with the same poles, current, and curve would give higher fault-clearing capacity but occupies the same DIN footprint and terminal range — check the required SCCR at your point of coupling before swapping."},{"question":"What compliance documentation does MGN60537 carry?","answer":"Certified to EN/IEC 60947-2. Suitability for isolation is confirmed per that standard. IP20 rated. Pollution degree 3. The Multi9 series generally carries CE, UKCA, and EAC marks for the European and Eurasian markets; specific UL/CSA listing varies by variant — verify the exact catalogue number against your local code requirements."},{"question":"How do I get current pricing and availability for MGN60537?","answer":"Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through independent distribution channels — no automated price or live count is published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60537","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60537 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}