{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60552","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60552","canonicalUrl":"https://aoctrl.com/schneider/MGN60552","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60552","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60N series, MGN60552 miniature circuit-breaker, 4-pole, D-curve, 32 A rated, 20 kA Icu at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"The MGN60552 is a Schneider Electric C60N miniature circuit-breaker from the Multi9 range, built for distribution panelboards and sub-distribution boards where a D-curve trip characteristic is needed. Rated 32 A at 50 °C per EN/IEC 60947-2, it protects motor, transformer, and lighting circuits with high inrush currents — the D-curve magnetic trip at 12 x In (±20%) means it rides through starting surges without nuisance tripping, then clears hard faults fast. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA Icu at 415 V AC, and 6 kA Icu at 440 V AC — all conforming to EN/IEC 60947-2. That 20 kA at 240 V gives headroom for high-fault panels near transformers or large motor banks. The 73 mm depth and 81 mm height fit standard distribution enclosures. Tunnel-type terminals accept 1.5 to 35 mm² flexible or rigid conductors; strip length 14 mm, torque to 3.5 N·m.","metaTitle":"MGN60552 C60N MCB, 32A 4P D-Curve, 20kA Icu, Multi9","metaDescription":"MGN60552 C60N miniature circuit-breaker. 32A rated, 4-pole D-curve, 20kA Icu at 240V AC. EN/IEC 60947-2. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"32 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/MGN60552/c60-circuit-breaker-c60n-4p-32a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60552/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60552 and how do I get a price?","answer":"The MGN60552 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is MGN60552's breaking capacity at 240 V AC?","answer":"The MGN60552 has a breaking capacity of 20 kA Icu at 240 V AC phase-to-phase, conforming to EN/IEC 60947-2."},{"question":"What wire size does the MGN60552 terminal accept?","answer":"Tunnel-type terminals accept 1.5 to 35 mm² flexible or rigid conductors, with a strip length of 14 mm and tightening torque of 3.5 N·m."},{"question":"What compliance documentation does this brand provide for MGN60552?","answer":"The MGN60552 is certified to EN/IEC 60947-2, with pollution degree 3, IP20 protection, and suitability for isolation per the same standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60552","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60552 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}