{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60553","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60553","canonicalUrl":"https://aoctrl.com/schneider/MGN60553","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60553","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60N, 4P D-curve miniature circuit breaker, 40 A rated at 50 °C, 20 kA Icu at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"The MGN60553 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range — a 4-pole (4P) unit with a D-curve thermal-magnetic trip, rated 40 A at 50 °C per EN/IEC 60947-2. That makes this breaker a natural fit for motor branch circuits, welding equipment, or any load with a high starting surge. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V — all per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of those figures: 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. That means after clearing a fault at the Ics level the breaker can be reclosed and continue service, which matters for uptime in a distribution board where a downstream fault shouldn't force a breaker swap. Rated operational voltage is 440 V AC, so it covers 400 V three-phase networks with headroom. The IP20 finger-safe terminals are fine inside a closed enclosure.","metaTitle":"MGN60553 C60N MCB, 4P D-Curve 40 A, 20 kA Icu, Multi9","metaDescription":"MGN60553 C60N miniature circuit breaker, 4P, D-curve, 40 A rated current, 20 kA Icu at 240 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"40 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/MGN60553/c60-circuit-breaker-c60n-4p-40a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60553/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60553?","answer":"The MGN60553 is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is MGN60553's D-curve trip threshold?","answer":"The D-curve magnetic trip fires at 12 x In (±20 %), so roughly 480 A instantaneous for this 40 A breaker."},{"question":"What compliance documentation does Schneider provide for MGN60553?","answer":"The breaker is certified to EN/IEC 60947-2 and carries an IP20 rating. Pollution degree 3 per the same standard is declared."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60553","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60553 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}