{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60625","canonicalUrl":"https://aoctrl.com/schneider/MGN60625","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN60625 miniature circuit-breaker, 6 A rated current, C curve, 2 poles, 30 kA Icu at 240 V AC, 35 mm DIN rail mount.","salesMarkdown":"The MGN60625 is a C60H miniature circuit-breaker from the Multi9 range, rated 6 A with a C curve and 2 poles. It breaks up to 30 kA Icu at 240 V AC phase-to-phase per EN/IEC 60947-2, which means it handles high fault currents typical in distribution panels without upstream coordination headaches. The 35 mm symmetrical DIN-rail mount and 36 mm width (2 x 18 mm pitches) fit standard panel layouts — that's another SKU that drops right into a populated enclosure. Rated 6 A at 50 °C per EN/IEC 60947-2, so it protects a 6 A branch circuit without derating at typical panel ambient. The C curve (magnetic trip at 8.5 x In ±20 %) suits moderate inrush loads like small motor starters or lighting contactors — it won't nuisance-trip on a 30 A cold-start surge but clears a dead short fast. Breaking capacity of 30 kA Icu at 240 V AC means it safely interrupts a fault up to that level; the service breaking capacity Ics is 15 kA (50 %) at the same voltage, so it can be reclosed after a fault within that range. Thermal-magnetic trip unit, 10,000 electrical cycles, 20,000 mechanical — solid for a distribution MCB. Tunnel terminals accept 1 to 25 mm² rigid or flexible (with or without ferrule), torque to 2 N·m. Wire strip length 14 mm. Comb busbar compatible top or bottom. IP20 finger-safe front. The ON/OFF toggle gives local indication — no separate aux contact needed for panel status.","metaTitle":"MGN60625 C60H MCB, 6 A C-curve 2P, 30 kA breaking capacity","metaDescription":"MGN60625 C60H miniature circuit-breaker, 6 A rated, C curve, 2 poles, 30 kA Icu at 240 V AC. EN/IEC 60947-2. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"2P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"6 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a1a56908389e3f340307fe6807fe2de1.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60625/c60-circuit-breaker-c60h-2p-6a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60625/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60625?","answer":"Sourced to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"What is the breaking capacity of MGN60625?","answer":"30 kA Icu at 240 V AC phase-to-phase per EN/IEC 60947-2, with 15 kA Ics (50 %) at the same voltage."},{"question":"What curve and poles does MGN60625 have?","answer":"C curve, 2 poles (2P). Magnetic trip at 8.5 x In ±20 %."},{"question":"What standards does MGN60625 comply with?","answer":"EN/IEC 60947-2, pollution degree 3, suitability for isolation per that standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}