{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60635","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60635","canonicalUrl":"https://aoctrl.com/schneider/MGN60635","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60635","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN60635 miniature circuit-breaker, 3 poles, C-curve, 2 A rated current, 30 kA breaking capacity at 240 V AC.","salesMarkdown":"The MGN60635 is a 3-pole miniature circuit-breaker (MCB) from the Schneider Electric Multi9 C60H series, rated 2 A at 50 °C with a C-curve trip characteristic (magnetic tripping at 8.5 x In ±20 %). It is designed for distribution applications and uses thermal-magnetic trip technology to protect branch circuits against overload and short-circuit currents. The breaking capacity is 30 kA Icu at 240 V AC (phase-to-phase, 50/60 Hz) per EN/IEC 60947-2, with 15 kA at 415 V AC, 10 kA at 440 V AC, and 25 kA at 125 V DC. The service breaking capacity Ics is 50 % of Icu at AC voltages (15 kA at 240 V, 7.5 kA at 415 V, 5 kA at 440 V) and 100 % (40 kA) at 125 V DC. Mounts on a 35 mm symmetrical DIN rail (6 module pitches of 9 mm each) and accepts tunnel-type terminals for 1–25 mm² conductors. The IP20 rating means it is suitable for installation inside an enclosure — not for wet or washdown areas. For a 2 A rating, that means magnetic pickup between 13.6 A and 20.4 A. The 10 kA at 440 V AC covers three-phase line-to-line faults at standard industrial voltages. The IP20 terminals and pollution degree 3 rating are part of the same standard certification.","metaTitle":"MGN60635 C60H Miniature Circuit-Breaker, 3P, C-Curve, 2 A, 3","metaDescription":"MGN60635 C60H MCB from Multi9 range, 3-pole, C-curve, 2 A rated, 30 kA breaking at 240 V AC. EN/IEC 60947-2. Current lifecycle stage. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"2 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 40 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/66ffa82acc7c560800bb3088332c108a.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60635/c60-circuit-breaker-c60h-3p-2a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60635/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60635","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60635 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}