{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60638","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60638","canonicalUrl":"https://aoctrl.com/schneider/MGN60638","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60638","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H Multi9 miniature circuit breaker, MGN60638, 6 A rated current, C-curve, 3-pole, 30 kA Icu at 240 V AC, 35 mm DIN rail mount.","salesMarkdown":"It's a 3-pole unit built to EN/IEC 60947-2, Category A, meaning it's designed for distribution-level overcurrent protection where the short-circuit rating matters more than selectivity coordination with downstream devices. Breaking capacity is 30 kA Icu at 240 V AC phase-to-phase, 15 kA at 415 V AC, and 10 kA at 440 V AC — all conforming to EN/IEC 60947-2. The Ics (service breaking capacity) is 50% of Icu at those AC voltages, and 100% at 125 V DC, so it clears faults and can be reclosed after a downstream event at the rated service level. Snaps onto 35 mm symmetrical DIN rail (EN 60715). The 54 mm width for 3 poles (6 x 9 mm pitches) is standard — fits a 6-module slot in any distribution board. Depth is 73 mm, which clears most standard enclosures; check gland-plate clearance if the panel is shallow. That's a solid connection for panel wiring — no ferrules needed for stranded, but they're fine if you use them. The C-curve trips magnetically at 8.5 x In (±20%), so the 6 A unit holds through motor inrush up to about 51 A peak and clears faster on higher faults. That's the standard choice for general distribution and moderate inductive loads — not for high-inrush transformers or long cable runs where a D-curve might be needed. The DC breaking capacity is 25 kA Icu at 125 V DC — useful for DC bus protection in drives or battery-backed circuits.","metaTitle":"MGN60638 C60H MCB, 6 A C-Curve 3P, 30 kA Breaking Capacity","metaDescription":"MGN60638 Schneider C60H miniature circuit breaker, 6 A rated, C-curve, 3-pole, 30 kA Icu at 240 V AC. EN/IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"6 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 40 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b4b7c7817d7ef68651f64696fbf3d8a5.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60638/c60-circuit-breaker-c60h-3p-6a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60638/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60638?","answer":"The MGN60638 has a breaking capacity of 30 kA Icu at 240 V AC phase-to-phase, 15 kA at 415 V AC, 10 kA at 440 V AC, and 25 kA at 125 V DC, all conforming to EN/IEC 60947-2."},{"question":"What is the closest alternative to MGN60638 in the C60 family?","answer":"Within the C60 range, the C60H (MGN60638) sits above the standard C60N on breaking capacity. The C60N offers lower Icu ratings (typically 10-15 kA at 240 V AC) for less demanding installations. The C60H is the right choice where higher fault current capability is specified on the single-line diagram."},{"question":"What compliance documentation does MGN60638 carry?","answer":"The MGN60638 is certified to EN/IEC 60947-2. It carries IP20 protection per that standard. The evidence does not list RoHS, REACH, or UL documentation specifically, but as a Schneider Multi9 product it typically meets EU directives — verify specific compliance documents with your order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60638","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60638 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}