{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60641","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60641","canonicalUrl":"https://aoctrl.com/schneider/MGN60641","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60641","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN60641 miniature circuit breaker, 3-pole, 20 A rated, C-curve, 30 kA Icu at 240 V AC, 25 kA at 125 V DC, EN/IEC 60947-2.","salesMarkdown":"The MGN60641 is a C60H miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C with a C-curve trip characteristic (magnetic trip at 8.5 x In ±20 %). The 30 kA Icu at 240 V AC phase-to-phase (EN/IEC 60947-2) tells you it can safely interrupt a fault up to that level without welding its contacts or cascading upstream; the 25 kA Icu at 125 V DC means it also handles DC distribution panels, common in battery-backed control circuits or solar combiner boxes. For a panel OEM wiring a 20 A lighting or small-power subfeed, this breaker meets it where it is: 3-pole, 35 mm DIN rail mount, tunnel terminals accepting 1–25 mm². The 54 mm width (6 x 9 mm pitches) occupies three standard module spaces in the enclosure. IP20 rated, so it lives inside a closed panel — no washdown exposure. The toggle gives local ON/OFF indication and a contact position indicator confirms isolation status (suitability for isolation is certified per EN/IEC 60947-2). Earth-leakage protection requires a separate block, not integrated.","metaTitle":"MGN60641 C60H MCB, 20 A C-Curve 3P, 30 kA at 240 V AC","metaDescription":"MGN60641 C60H miniature circuit breaker, 20 A rated, C-curve, 3-pole, 30 kA breaking capacity at 240 V AC, 25 kA at 125 V DC. EN/IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"20 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 40 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/17469ae682c544cd17094267fa26e9f2.pdf","sourceUrl":"https://www.se.com/sg/en/product/MGN60641/c60-circuit-breaker-c60h-3p-20-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60641/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60641","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60641 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}